3. TECHNICAL DATA
3.1 Phoenix xx/220
TECHNICAL DATA
4)
Cont. output at 25°C
Cont. output power at 25°C
Cont. output power at 40°C
Peak power
Output voltage
Output frequency
Output waveform
Total harmonic distortion
Admissible cos ϕ of load
Input voltage (±3% tol.):
Nominal
Range
Maximum efficiency
No load power consumption at
nominal input voltage
[economy]
Operating temperature range
(ambient)
Economy threshold
Protections against
Indications (by pre-
programmed flashing
sequences of the power LED)
DC input connection
AC output connection
Enclosure body size
(l x h x w)
Protection class
Total weight
The inverter complies with the
following standards :
victron energy
Ph 12/220
Ph 24/220
220VA
220VA
1)
175W
175W
1)
150W
150W
350W
400W
230Vac ± 2% or 115Vac ± 2%
50Hz ± 0.05% or 60Hz ± 0.05%
True sinewave
Maximum 5%
0.6 – 1
12Vdc
24Vdc
2)
2)
10.5
– 16Vdc
21
– 31Vdc
90%
91%
< 2.8W
< 3W
[0.6W]
[0.8W]
-20 °C to +50 °C
Pout = 12W
Pout = 15W
Short circuit, overload, high temperature and
low battery voltage
Power on, short circuit/overload, high
temperature, high/low battery voltage and
economy mode
Two wires, length 1.5 meters, ∅ 4mm²
IEC-320 AC outlet
154 x 98 x 130 (without mounting brackets)
IP20
2.3 kg
2.3 kg
EN50081-1 Generic Emissions Standard
EN50082-1 Generic Immunity Standard
EN60335-2 Safety Standard
manual
Ph 48/220
220VA
175W
150W
400W
3)
48Vdc
2)
41
– 60Vdc
93%
< 4W
[1.2W]
Pout = 15W
2.4 kg
17