Problem
Audible or visual alarm is
on.
The lamp does not work.
The lamp does not work.
The compressor operates
continually.
The compressor does not
start immediately after
pressing the FastFreeze
or after changing the tem‐
perature.
Water flows inside the re‐
frigerator.
Water flows on the floor.
Possible cause
The cabinet has been re‐
cently switched on or the
temperature is still too
high.
The temperature in the
appliance is too high.
The lamp is in stand-by
mode.
The lamp is defective.
Temperature is set incor‐
rectly.
Many food products were
put in at the same time.
The room temperature is
too high.
Food products placed in
the appliance were too
warm.
The FastFreeze function
is switched on.
This is normal, no error
has occurred.
The water outlet is clog‐
ged.
Food products prevent
water from flowing into
the water collector.
The melting water outlet
is not connected to the
evaporative tray above
the compressor.
ENGLISH
Solution
Refer to "Door Open
Alarm"or "High Temperature
Alarm".
Refer to "Door Open
Alarm"or "High Temperature
Alarm".
Close and open the door.
Contact the nearest Author‐
ised Service Centre.
Refer to "Operation"/"Control
panel" chapter.
Wait a few hours and then
check the temperature
again.
Refer to climate class chart
on the rating plate.
Allow food products to cool
to room temperature before
storing.
Refer to "FastFreeze func‐
tion".
The compressor starts after
some time.
Clean the water outlet.
Make sure that food prod‐
ucts do not touch the rear
plate.
Attach the melting water out‐
let to the evaporative tray.