Factory Settings - Bodet Harmonys 607725 I Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6/ Connect the power supply,
Wiring of the electronic board:
1
2
1
1st Louspeaker
2
2nd Loudsapeaker (ref: 907731)
3
Power supply 24VDC
4
Ethernet network RJ45
It is imperative that the equipment be switched on only after the installation is
completed and controller casing closed.

2.2 Factory settings

7
8
9
When the power is on, press the test button (until you hear a «beep» continuously).
The default configuration is as follows :
- Name : BODET-MAC address
- IP configuration by DHCP
- Multicast synchronisation (broadcast)
- Synchronisation address: 239.192.55.1
- Volume : level 5
- Zone number : 1
3
4
Power supply indicator :
7
LED ON (green) = device powered on.
LED OFF = no power.
Network indicator :
8
LED flashing green flash = connection to the network in
progress.
LED flashing green slowly = device connected to the network
LED flashing red slowly = loss of network connection or
failure to connect to the network.
Test button :
9
Pressing = the product emits a «bip».
Pressing at the power on = return to factory configuration
Power Wiring:
5
6
L: brown
5
N: blue
Earth: yellow/green
6
To electronic card 24VDC
17

Publicité

Table des Matières
loading