SE Cleanheat- smoke exemption modification
Smoke exempt models are factory fitted with a air stop on the air
control slider: The adjust control to smoke control settings place Allen
key on bolt in the air intake ( at the rear of the stove ensuring that the
air control is limited to
● Woodland
SE air stop restriction Woodland 5kW
Normal travel 40mm
restricted travel for SE Model 30mm (25%)
LIGHTING THE STOVE - SOLID FUELS
Note: on cold days it maybe necessary to warm the flue using two firelighters.
1. Place Firelighters and a few smaller pieces of dry wood (kindling) among a small quantity of fuel in the combustion
chamber.
2. Fully slide open (pull out fully) the Universal air control (UAC) air slider below the stove door. Slide fully to the left position.
The stove now has total primary air for start up. (It maybe necessary to pull open ash pan 2 mm in some conditions.).
Light firelighters and securely close door.
3. With the fire established, open the door. And fill chamber with fuel, (see weight table on page 3) do not overload. (do
not cover tertiary air ports). Reloading is approximately every hour.
4. Close fire door, set UAC control to mainly primary and 80% open.
5. Adjust as necessary.
Re-fueling solid fuel
To re-fuel your stove.
Before refuelling, open UAC control to primary and fully open.
Open door gently and de -ash your stove with use of poker. (not provided)
Add fuel to below tertiary air bar (see weight table on page 3) and close the door.
Leave the air controls open whilst fuel is established. Once established set UAC control to mainly primary and 80% open.
In the event of a chimney fire: Close the air controls and the stove door, and call 999 or your local fire brigade.
If your stove is overheating close all air sliders and door , leave until the stove has returned to normal temperature.
The stove is only suitable for intermittent use only: do not run overnight or for long periods unattended.
Experience will determine the settings that produce best results. Use a flue thermostat to check the stove is not overheating.
Flue thermostats should be placed directly above collar of the stove on a non insulated section of pipe. (efficient operating
temperature range is between 100c and 200c) The stove will get very hot during use and due care must therefore be exercised.
Please use the glove and operating tool supplied when operating air controls and door.
SOLID SMOKELESS FUELS-
The Woodland model is suitable for use with good quality smokeless fuels and has been fully tested to the relevant European
standard. Only use registered smokeless fuels on this stove. Take special note of load quantities in this book.(page 5)
HOUSE COAL AND PETROLEUM COKE ARE NOT SUITABLE FOR USE ON
THIS STOVE; ITS USE WILL INVALIDATE THE GUARANTEE.