Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

OPERATION AND INSTALLATION MANUAL
MULTI-FUEL & SMOKE EXEMPTION MODELS
Guide d'utilisation et Mode d'Emploi
THE WOODLAND & THE WOODLAND LARGE
The Woodland SE
The Woodland
Logstore SE
The Woodland
Convection SE
The Woodland
Convection Logstore
M00530-00-00-00-01
M00531-00-00-00-01
M00533-00-00-00-00
M00534-00-00-00-00
The Woodland Large
SE
The Woodland Large
Logstore SE
The Woodland Large
Convection SE
The Woodland Large
Convection Logstore
1
ENG/FR
March 2019
M00830-00-00-00-00
M00831-00-00-00-00
M00832-00-00-00-00
M00833-00-00-00-00

Publicité

Table des Matières
loading

Sommaire des Matières pour Mendip Stoves THE WOODLAND

  • Page 1 ENG/FR March 2019 OPERATION AND INSTALLATION MANUAL MULTI-FUEL & SMOKE EXEMPTION MODELS Guide d’utilisation et Mode d'Emploi THE WOODLAND & THE WOODLAND LARGE The Woodland SE The Woodland Large M00530-00-00-00-01 M00830-00-00-00-00 The Woodland The Woodland Large M00531-00-00-00-01 M00831-00-00-00-00 Logstore SE...
  • Page 2 WOODLAND LARGE THE WOODLAND WOODLAND LOGSTORE / LOGSTORE / RANGE-BÛCHE WOODLAND LARGE / GRAND RANGE-BÛCHE GRAND HEIGHT /Hauteur A 615 mm 775 mm 665 mm 825 mm WIDTH / Largeur B 570 mm 570 mm 570 mm 570 mm DEPTH / Profondeu...
  • Page 3: Pièces Détachées, Vue Éclatées, Assemblage

    This manual refers to the stoves listed above, which are tested in accordance with EN 13240. Thank you for purchasing your new stove from Mendip Stoves. Please read this manual carefully to ensure that you get maximum enjoyment and performance from your new stove and to prevent any potential operational problems. Please note that “all local regulations, including those referring to national and European Standards, need to be complied with when...
  • Page 4: Health And Safety Precautions

    The use of any aerosol around lit stove is dangerous and care must be take in handling aerosols. IMPORTANT: hese instructions cover the basic principles to ensure the satisfactory installation of Mendip Stoves product :- Woodland models, although detail may need slight modification to suit particular local site conditions.
  • Page 5 Older properties, especially, may have chimney faults or the cross section may be too large . Mendip Stoves recommend the use of a solid fuel flue lining system for all installation into existing chimneys. All chimney systems must be used in accordance with Building Regulations Approved Document J.
  • Page 6 STOVE PERFORMANCE & TESTING Mendip Stoves, The Woodland models are tested in accordance with EN 13240. Output Efficiency CO@13% Suitable for Output Coal Efficiency CO@13% O₂ Wood Fuel O₂ DEFRA Smoke Fuel Control Zones Woodland 5.0kW 81.1% 0.06 Yes / SE model 5.0kW...
  • Page 7 The hearth should be able to accommodate the weight of the stove and its chimney if the chimney is not independently supported. The Woodland stoves have been tested and are suitable to be installed on a 12 mm non combustible plate, such as 12 mm glass plates .
  • Page 8 HOW TO FIT A WOODLAND LOGSTORE Remove the internal components of the stove and fill the Tilt the stove onto it’s side to allow easy and safe access chamber with material to prevent the bricks from falling. to the feet. Unscrew the levelling bolts at the foot of the Additionally, prepare a soft elevated surface.
  • Page 9 Connection to chimney Mendip Stoves are built with a top flue outlet as standard, this can be altered to a rear connection by removing the top collar, rear cover plate then exchanging collar and plate. Care should be taken to ensure an airtight fit when refitting collar and plate.
  • Page 10 OPERATING YOUR STOVE - THE MK.4 AIR CONTROL LEVER The Universal air controller provides air control for the whole stove from a single lever. The Lever has two key operations Increased Air Supply Decreased Air Supply Moving the control lever in and out Sliding the control lever in reduces and out increases the total...
  • Page 11 HOW TO LIGHT YOUR WOODBURNING STOVE Note: If the chimney is externally fitted or the stove has been installed on a larger diameter clay chimney liner then on cold days it maybe necessary to warm the flue using firelighters prior to lighting with wood. 1.
  • Page 12 DO NOT BURN HOUSE COAL. DO NOT BURN HOUSEHOLD WASTE. THIS APPLIANCE IS NOT AN INCINERATOR. MENDIP STOVES RECOMMEND THE USE OF A FLUE THERMOSTAT TO CHECK YOUR STOVE IS NOT OVERHEATING. PLACE FLUE THERMOSTAT DIRECTLY ABOVE COLLAR OF STOVE AND REFER TO TEMPERATURE GAUGE ON PAGE 6.
  • Page 13 RE-FUELLING WHEN BURNING WOOD Adding fuel to your stove when you only have glowing embers,and the flames have died down, is the cleanest way to refuel your stove. 1. Before refuelling, open the Universal Air Control (UAC) fully and slide to the central position. 2.
  • Page 14 SOLID SMOKELESS FUELS- The Woodland model is suitable for use with good quality smokeless fuels and has been fully tested to the relevant European standard. Only use registered smokeless fuels on this stove. Take special note of load quantities (page 6).
  • Page 15 MAINTENANCE Mendip stoves recommends that your model needs to have the ash removed from the stove at regular intervals (weekly if used daily). Allowing the ash pan to over flow can impede the function of the stove and can cause possible damage to the stove grate and ash pan.
  • Page 16 Clean Air Act requirements. The Woodland Mk.4 SE and Woodland Large stoves have been recommended as suitable for use in smoke control areas when burning wood logs. The appliances can also burn authorised fuels in smoke control areas.
  • Page 17: Pièces Détachées, Vue Éclatées

    STOVE PARTS, COMBUSTION CHAMBER, ASSEMBLY PIÈCES DÉTACHÉES, VUE ÉCLATÉES "This section shows the parts contained in your stove, each stove has over 80 spare-parts and, each part is detailed. When new parts are required the section will allow spares to be recognised and ordered. As a further source of reference please visit www.eurostove.co.uk for latest spare-part information.
  • Page 18: Montage Et Démontage De L'intérieur

    HOW TO REMOVE THE WOODBURNERS INTERNAL PARTS MONTAGE ET DÉMONTAGE DE L’INTÉRIEUR To remove the vermiculite brick set take the following steps: Remove both of the vermiculite baffle bricks by lifting and tilting each brick in turn. To create more room to remove the first brick, lift up the adjacent baffle and rest a larger amount on the side brick. It is now possible to remove both side bricks;...
  • Page 19: Les Chambre De Combustion

    WOODLAND DOOR ASSEMBLY ECLATE DE PORTE To find out more details, as well as to get prices and availability of these parts, please visit: www.eurostove.co.uk/the-woodland-furnace-door WOODLAND COMBUSTION CHAMBER LES CHAMBRE DE COMBUSTION To find out more details, as well as to get prices and availability of these parts, please visit: www.eurostove.co.uk/mp-woodland-mk4-fire-bricks www.eurostove.co.uk/mp-woodland-large-fire-bricks...
  • Page 20: Le Woodland Liste Des Pièces

    WOODLAND MK4 PARTS LIST Le Woodland Liste des Pièces To find out more details, as well as to get prices and availability of these parts, please visit: www.eurostove.co.uk/mp-woodland-mk4-spares www.eurostove.co.uk/mp-woodland-large-spares...
  • Page 21: Consignes Generales De Sante Et De Securite

    Ce manuel se réfère aux poêles énumérés ci-dessus. Ils ont été testés conformément à la norme EN 13240. Nous vous remercions d'avoir choisi un nouveau poêle de Mendip Stoves et nous sommes certains que vous en serez enchantés. Lisez ces instructions, elles relatent les principes de base pour assurer l'installation satisfaisante de votre poêle,...
  • Page 22: Cheminée Et Raccordement Au Poêle À Bois

    à-dire, plus de 160 mm x 160 mm. La société Mendip Stoves conseille l'utilisation d'un système de conduit de fumée de combustibles solides pour l'installation dans des cheminées existantes. Tous les systèmes de cheminée doivent être utilisés conformément au Règlement de construction approuvé.
  • Page 23: Indices De Performance Et Résultat Des Tests

    INDICES DE PERFORMANCE ET RÉSULTAT DES TESTS Poêles à bois sont conforme au standard EN 13240. Puissance Rendement CO@13% O₂ Puissance Rendement CO@13% O₂ bois charbon Le Woodland 5.0kW 81.1% 0.06 5.0kw 0.17 Le Woodland Grand 7.5 kW 79.3% 0.09 7.0kW 0.11 Max longueur de bûche, Quantité...
  • Page 24: Mis En Service

    NE PAS BRÛLER DU CHARBON BRUN. NE PAS BRÛLER DES DÉCHETS DOMESTIQUES, CET APPAREIL N’EST PAS UN INCINERATÉUR MENDIP STOVES conseille l'utilisation d’un THERMOSTAT de cheminée pour vérifier que votre poêle ne surchauffe pas. Mettez le THERMOSTAT DIRECTEMENT AU-DESSUS DU POELE sur le conduit et comparer aux TEMPERATURES de...
  • Page 25: Premier Allumage De Votre Poêle

    PREMIER ALLUMAGE DE VOTRE POÊLE Avant d’allumer le premier feu dans le poêle Assurez-vous que vous avez lu ce manuel entièrement et vous familiariser avec les contrôles de votre poêle. La peinture du poêle résistante à la chaleur, "cuira" et durcira la première fois que vous allumerez votre poêle. Le procédé de durcissement produit beaucoup de fumée et une forte odeur.
  • Page 26: Comment Allumez Votre Poêle À Bois Mendip

    COMMENT ALLUMEZ VOTRE POÊLE À BOIS MENDIP Remarque : Si la conduit est à l’extérieure et en période de grand froid, il peut être nécessaire de réchauffer la cheminée en utilisant les allume-feux préalable à l'allumage avec du bois 1. Placez des petits bouts de bois sec (petit bois) dans le foyer par-dessus les allume-feux non toxiques.
  • Page 27: Chargement De Bois

    FONCTIONNEMENT PENDANT LA NUIT Mendip Stoves sont conçus pour brûler du bois et du Charbon sans fumée de qualité Comme un régime de temps de nuit, nous recommandons que la chamber de combusion est chargé quand il est chaud et brûlé...
  • Page 28: Diagnostic Des Problèmes

    ATTENTION Correctement installé, exploité et entretenu, votre poêle n’émettra pas de fumées dans l'habitation. Des Fumées occasionnelles lors du décendrage et du ravitaillement en bois peuvent se produire. Cependant, les émissions de fumées persistantes sont potentiellement dangereuses et ne peuvent pas être tolérées. Si les émissions de fumée persistent, suivez ces instructions: a) Ouvrez les portes et les fenêtres pour ventiler la pièce, puis quittez les lieux.
  • Page 29: L'entretien Annuel

    MAINTENANCE Mendip Stoves recommande de nettoyer régulièrement votre poêle, retirez la cendre (hebdomadaire si l’utilisation est quotidiennement). Utiliser un cendrier rempli par trop de cendre peut entraver le fonctionnement du poêle et peut causer des dommages sur la grille du poêle et sur le cendrier. Pour enlever le bac à cendre, utiliser l'outil et l’accrocher sur le devant du cendrier.
  • Page 30: Comment Installer Les Pattes D'un Range-Bûches D'un Woodland

    COMMENT INSTALLER LES PATTES D'UN RANGE-BÛCHES D'UN WOODLAND Retirez les composants internes du poêle et remplissez la Inclinez le poêle sur son côté pour permettre un accès chambre avec un matériau empêchant les briques de facile et sûr aux pieds. Dévissez les boulons de mise à tomber.
  • Page 32 Mendip Stoves Ltd. Unit H1 Mendip Industrial Estate Mendip Road Rooksbridge Somerset BS26 2UG Website www.mendipstoves.co.uk Email info@eurostove.co.uk Telephone 01934 750 500 Distribué en France par la société / Distributed in France and Benelux by: Eurostove SAS Centre d’Affaires Rue de L’horlogerie BP 60011 62401 Bethune Cedex Contact@eurostove.fr...

Table des Matières