Mendip Stoves Somerton SG Guide D'utilisation Et Mode D'emploi page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DISTANCE TO COMBUSTIBLE MATERIAL MEASUREMENTS
Distance to Combustible materials
Combustible materials should not be located where the heat dissipating through the walls of fireplaces or flues could
ignite it. Therefore when installing the stove in the presence of combustible materials due account must be taken of the
guidance on the separation of combustible material given in Building Regulations Approved Document J and also in these
stove instructions.
The minimum distances to flammable materials are specified on the EN 13240 plate on the back of the stove.
Somerton side glass
When positioning the stove in a
corner position with combustible
walls the stove must be 150mm at
the corners points to achieve
500mm from the side glass to the
side wall.
If the walls are non combustible the
corner positions can be 100mm
When positioning the stove against
a combustible wall the stove must
be 100mm .
Care must taken to ensure
combustible items are not within
500mm of the sides of the stove.
Disctance to
Distance to
combustibles rear
combustibles sides
100mm
500mm
500mm
Distance to soft furnishings
Distance to Soft
500mm
furnishings front
1000mm
150mm
500mm
100mm
1000mm
6
Suitable for 12mm non-
combustible floor plate
YES
500mm
150mm
Combustible wall
Combustible wall
500mm

Publicité

Table des Matières
loading

Table des Matières