Mendip Stoves Somerton SG Guide D'utilisation Et Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SE - smoke exemption modification
Smoke control models are factory fitted with
a air stop on the air control slider.
Somerton SG Model
WARNING NOTE
Properly installed, operated and maintained this stove will not emit fumes into the dwelling. Occasional fumes from
de-ashing and re-fuelling may occur. However, persistent fume emission is potentially dangerous and must not be
tolerated. If fume emission does persist, then the following immediate action should be taken:-
(a) Open doors and windows to ventilate the room and then leave the premises.
(b) Let the fire go out.
(c) Check for flue or chimney blockage and clean if required
(d) Do not attempt to relight the fire until the cause of the fume emission has been identified and corrected. If necessary
seek expert advice.
The most common cause of fume emission is flue way or chimney blockage. For your own safety these must be kept clean
at all times.
CO Alarm
Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm sounds unexpectedly, follow the
instructions given under "Warning Note" above.
Aerosols
Aerosols are flammable and therefore dangerous to use around a lit stove. Do not use aerosols sprays near your lit stove.
The use of any aerosol is dangerous and care must be take in handling aerosols.
TROUBLE SHOOTING
1. Fire Will Not Burn - check
a) the air inlet is not obstructed in any way,
b) that chimney and flue ways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply into the room,
e) that an extractor fan is not fitted in the same room as
the fire.
2. Fire Blazing Out Of Control - check
a) the doors are tightly closed,
b) the air controls are turned down to the minimum
setting,
c) the flue damper is closed ( if fitted),
d) a suitable fuel is being used,
e) the door seals are in good condition.
F) the chimney draft may be too strong
G) check ash pan seal and
H) check for ash below ash pan causing pan to seat
incorrectly and clean out.
SE air stop restriction Somerton SG 7kW
Normal travel 40mm
restricted travel for SE Model 20mm
(50%)
3) Soot forms on the window
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
c) fire not hot enough
4) The stove fails to heat fully
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
5) Smoke or odour
a) weak chimney draft
b) check for blockages in the flue pipe/chimney
c)
6) Soot in the chimney
a) The firewood may be too wet
b) intake of secondary air may be insufficient
12
...\Mendip stoves Air box 7 kW S...
check the height of the chimney relative to the
surroundings