REFUELLING WHEN BURNING WOOD
To re-fuel your stove in the cleanest way only refuel your stove when flames have died down and you have glowing embers.
Before refuelling, open UAC fully and slide to the central position . Unlatch door to equalise pressure with the room.
Open door gently, add two pieces of wood (please check weight table page 5) and close the door.
Once the flames from the logs are fully established slide UAC control to right position and push air control in by 25%.
The stove is only suitable for intermittent use only: do not run overnight or for long periods unattended. Experience will
determine the settings that produce best results. Use a flue thermostat to check the stove is not overheating.
Flue thermostats should be placed directly above collar of the stove on a non insulated section of pipe. (efficient operating
temperature range is between 200c and 400c)
BURNING WOOD IN A SMOKE CONTROL AREA
You must purchase a smoke control version of the Mendip stove which is modified slightly to comply with regulations. Any
change to this modification will invalidate the stoves compliance for smoke control areas.
"The Clean Air Act 1993 and Smoke Control Areas"
Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control
area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a
designated smoke control area. It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area
unless it is used in an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control area).
In England appliances are exempted by publication on a list by the Secretary of State in accordance with changes made to
sections 20 and 21 of the Clean Air Act 1993 by section 15 of the Deregulation Act 2015. Similarly in Scotland appliances are
exempted by publication on a list by Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014. In
Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and by the Department of the
Environment respectively. Further information on the requirements of the Clean Air Act can be found here:
https://www.gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation and supervision of smoke
control areas and you can contact them for details of Clean Air Act requirements"
Only specific SE cleanheat models are suitable for smoke control areas (page 5), alterations should not be attempted.
Mendip smoke control stoves should not be burnt with the door left open.
The refuelling procedure : - allow the newly charged fuel to burn with the secondary air control set at maximum for up 3
to 4 minutes. After this period, with flames from the logs fully established, close the secondary air supply to the low
output setting. When operating at high output (secondary air set fully open) the new refuel charge does not require any
boost air to establish combustion.
Somerton SG
Refuelling on to a low fire bed
If there is insufficient burning material in the firebed to light a new fuel charge, excessive smoke emission can occur. Refuelling
must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable
period. If there are too few embers in the fire bed, add suitable kindling to prevent excessive smoke
Operation with door left open
Operation with the door open can cause excess smoke. The appliance must not be operated with the appliance door left
open except as directed in the instructions.
Dampers left open
Operation with the air controls or appliance dampers open can cause excess smoke. The appliance must not be operated
with air controls, appliance dampers or door left open except as directed in the instructions.
Fuel Overloading
The maximum amount of fuel specified in this manual should not be exceeded, overloading can cause excess smoke
Log Lenght
Max Log
SE Dimensions
length
L X W X D
35cm
250 x 110 x 110
Wood
reload
No logs
2
0.75hr
11
Weight
Maximum wood
wood load
moisture content
1.63kg
>20%