A)
(3)
Battery
A)
(4)
Battery release button
(5)
"Automatic shutdown (ABR)" button
(6)
"PowerLight" lamp
(7)
"Automatic shutdown (ABR)" LED
(8)
Rotational direction switch
(9)
On/off switch
(10) Handle (insulated gripping surface)
(11) Application tool (e.g. impact socket)
A) Accessories shown or described are not included with the
product as standard. You can find the complete selection of
accessories in our accessories range.
Technical Data
Cordless Impact Wrench
Article number
Rated voltage
A)
No-load speed
A)
Impact rate
A)
Max. torque
Machine screw diameter
Tool holder
Weight according to
B)
EPTA-Procedure 01:2014
Recommended ambient tem-
perature during charging
Permitted ambient temperat-
C)
ure during operation
and
during storage
Recommended rechargeable
batteries
Recommended chargers
A) Measured at 20−25 °C with rechargeable battery GBA 18V
3.0Ah.
B) Depends on battery in use
C) Limited performance at temperatures <0 °C
Noise/vibration information
Noise emission values determined according to
EN 62841-2-2.
Typically, the A-weighted noise level of the power tool is:
Sound pressure level 102 dB(A); sound power level
113 dB(A). Uncertainty K = 3 dB.
Wear hearing protection!
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 62841-2-2:
Tightening screws and nuts of the maximum permitted size:
2
2
a
 < 14.5 m/s
, K = 1.5 m/s
h
Bosch Power Tools
The vibration level and noise emission value given in these
instructions have been measured in accordance with a
standardised measuring procedure and may be used to com-
pare power tools. They may also be used for a preliminary
estimation of vibration and noise emissions.
The stated vibration level and noise emission value repres-
ent the main applications of the power tool. However, if the
power tool is used for other applications, with different ap-
plication tools or is poorly maintained, the vibration level
and noise emission value may differ. This may significantly
increase the vibration and noise emissions over the total
A)
working period.
To estimate vibration and noise emissions accurately, the
times when the tool is switched off or when it is running but
not actually being used should also be taken into account.
This may significantly reduce vibration and noise emissions
over the total working period.
GDS 250-LI
Implement additional safety measures to protect the oper-
3 601 JG6 1..
ator from the effects of vibration, such as servicing the
power tool and application tools, keeping their hands warm,
V=
18
and organising workflows correctly.
-1
min
0–2 400
-1
min
0–3 300
Assembly
Nm
250
u
mm
M10–M18
∎ ½"
kg
1.9–2.0
°C
0 to +35
Battery charging
Note: The battery is supplied partially charged. To ensure
°C
–20 ... +50
full battery capacity, fully charge the battery in the charger
before using your power tool for the first time.
The lithium-ion battery can be charged at any time without
GBA 18V...
reducing its service life. Interrupting the charging process
ProCORE18V...
does not damage the battery.
GAL 18...
The lithium-ion battery is protected against deep discharge
GAX 18...
by the "Electronic Cell Protection (ECP)". When the battery
GAL 36...
is discharged, the power tool is switched off by means of a
protective circuit: The application tool no longer rotates.
u
Removing the Battery
The battery (3) is equipped with two locking levels to pre-
vent the battery from falling out when pushing the battery re-
lease button (4) unintentionally. As long as the battery is in-
serted in the power tool, it is held in position by means of a
spring.
To remove the battery (3), press the release button (4) and
pull the battery out of the power tool. Do not use force to
do this.
Battery charge indicator
The green LEDs on the battery charge indicator indicate the
state of charge of the battery. For safety reasons, it is only
Remove the battery from the power tool before carry-
ing out work on the power tool (e.g. maintenance,
changing tool, etc.). The battery should also be re-
moved for transport and storage. There is risk of injury
from unintentionally pressing the on/off switch.
Do not continue to press the On/Off switch after the
power tool has automatically switched off. The battery
can be damaged.