Installation example for a stove/pellet stove

Skylight shaft
T fitting for condensation
Smoke duct:
use of a non-insulated
tube
Use and maintenance manual R-Evolution 11
Protection from rain
Insulated chimney
Grille for air passage into the
skylight shaft with opening for
inspecting the chimney
Fig.1
NO
Ashes deposited in the
90° bend
Protection from rain
Insulated chimney
T Fitting
Combustion ashes
collectiohamber
+ condensatioap
T fitting for condensation
Fig.3
This type of installation (See Fig.1) requires an insulated
chimney pot, even if the entire conduit is installed inside
the building. Besides, the structure must be inserted into a
properly ventilated skylight shaft.
In the lower part of the chimney pot there is an inspectioover,
properly isolated from wind and rain.
It is prohibited to install a 90° bend for the initial segment,
since the ashes would quickly obstruct smoke passage,
causing draught problems in the stove. (See Fig. 2)
It is possible to use an existing chimney or a shaft via ducting.
For this type of installation the standards on ducted smoke
evacuatioystems must be complied with. In the lower part of
the chimney pot, inside the home, there is a "T" type fitting
installed; externally there is another one installed, so that the
outside sectioan be inspected.
It is prohibited to install two 90° bend, since the ashes would
quickly obstruct smoke passage, causing draught problems in
the stove. (See Fig. 2)