Replacing the fuse

If the lamp burns out, the fine-wire fuse of the device might fuse, too. Only replace the fuse by a fuse of
same type and rating.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anti-
clockwise).
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing and fix it.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers only
in order to avoid hazards.
Should you have further questions, please contact your dealer.

TECHNICAL SPECIFICATIONS

Power supply:
Power consumption:
Dimensions (LxWxH):
Weight:
Maximum ambient temperature T
Maximum housing temperature T
Min.distance from flammable surfaces:
Min.distance to lighted object:
Fuse:
Accessory:
OMNILUX UV lamp 400W E-40
IWASAKI EYE UV-lamp E40/400W HQV400
Safety bond AG-15 4x1000mm up to 15kg
Please note: Every information is subject to change without prior notice. 23.07.2009 ©
230 V AC, 50 Hz ~
700 W
355 x 355 x 305 mm
9 kg
:
45° C
a
(steady state): 120° C
B
0.5 m
1 m
T 5 A, 250 V
Article No.:
No. 89514005
No. 91300400
No. 58010364
18/32