3. Safety Distances

Within a radius of 60 cm in front of and 55 cm
around the stove, fl ammable, combustible, or heat-
sensitive materials (e.g. furniture, wood or plastic
panelling, curtains, etc.) are not allowed to be loca-
ted in the heat radiating area of the fire box window
(fig. 1).
Behind the stove, outside the area of radiation, a
distance of 8 cm must be maintained to any flam-
mable materials (fig. 1).
WARNING!
Flammable flooring materials (e.g., wood,
laminate, carpeting,) must be protected
with a floorplate made of non-combustible
material (e.g., tiles, safety glass, slate, or
sheet steel).
The size of the floorplate must be larger
than the base of the stove by at least 50
cm in front and at least 28 cm at the sides
of the stove (fig. 2).
48
55
55
55
60
fig. 1
Dimensions in cm
28
28
floorplate
50
fig. 2
Dimensions in cm
4. Connection of Multiple Devices in
Direct Vent Operation
When the Asmara is operated as a direct vent mo-
48
del, more than one device can be connected to the
chimney under the following conditions:
55
CAUTION!
All connected fireplace stoves must be in
60
the same building unit or in the same ef-
fective area of the ventilation system.
The inlets for the combustion air ducts are
located in areas of equal pressure (same
pressure ratios), wind-induced pressure
fluctuations have to be avoided.
The inlets for the combustion air ducts are
located in areas of equal pressure (same
pressure ratios), wind-induced pressure
fluctuations have to be avoided.