Burner and nozzle specifications
Table 1
Burner
Fast (Large) (R)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Supply
pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
***
Butane
Natural
A
R
S
EHP 640 (X) /HA
Diameter
Thermal Power
(mm)
kW (p.c.s.*)
Nom.
Red.
100
3.00
0.70
75
1.65
0.40
55
1.00
0.40
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
P.C.S. = 50.37 MJ/Kg
P.C.S. = 49.47 MJ/Kg
P.C.S. = 37.78 MJ/m3
S
Liquid Gas
By-pass
Nozzle
1/100
1/100
(mm)
(mm)
***
39
86
218
28
64
120
28
50
73
37
25
45
Naturale Gas
Flow*
Nozzle
Flow*
g/h
1/100
l/h
(mm)
**
214
116
286
118
96
157
71
71
95
28-30
20
20
17
35
25