Performance Data Sheet - Whirlpool IKEA W11105307A Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model P8WB2L/P8RFWB2L (EDR1RXD1, Filter 1) Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA 483.1** for the reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA 483.1**
**Certified to CSA B483.1 only for use in Refrigerator applications.
Substance Reduction Aesthetic
Effects
Chlorine Taste/Odour
Particulate Class I*
Contaminant Reduction
Lead: @ pH 6.5 / @ pH 8.5
Benzene
p-Dichlorobenzene
Carbofuran
Toxaphene
Atrazine
Asbestos
Live Cysts
Turbidity
Lindane
Tetrachloroethylene
o-Dichlorobenzene
Ethylbenzene
1,2,4-Trichlorobenzene
2,4 - D
Styrene
Toluene
Endrin
Atenolol
Trimethoprim
Linuron
Estrone
Nonylphenol
Carbamazepine
Phenytoin
Naproxen
Bisphenol A
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.89 lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F
(20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
■ It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
■ The disposable cartridge must be changed at least every 6 months.
■ Use replacement filter P8RFWB2L, part #EDR1RXD1/EDR1RXD1B..
2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices
are subject to change without notice.
■ The filter monitor system measures the amount of water that passes
through the filter and alerts you when it is time to replace the filter.
Refer to the "Using the Controls" or "Water Filtration System" section
(in the User Instructions or User Guide) to learn how to check the
water filter status.
■ After changing the water filter, flush the water system. See "Water and
Ice Dispensers" or "Water Dispenser" in the User Instructions or User
Guide.
■ These contaminants are not necessarily in your water supply. While
testing was performed under standard laboratory conditions, actual
performance may vary.
■ The product is for cold water use only.
*Class I particle size: >0.5 to <1 um
Based on the use of Cryptosporidium parvum oocysts
Fibers greater than 10 um in length
††
®NSF is a registered trademark of NSF International.
24

PERFORMANCE DATA SHEET

Water Filtration System
System tested and certified by NSF International against
NSF/ANSI Standard 42, 53, 401 and CSA B483.1** for
the reduction of claims specified on the Performance
Data Sheet.
Influent Challenge
Concentration
2.0 mg/L ± 10%
At least 10,000 particles/mL
Influent Challenge
Concentration
0.15 mg/L± 10%
0.015 mg/L ± 10%
0.225 mg/L ± 10%
0.08 mg/L ± 10%
0.015 ± 10%
0.009 mg/L ± 10%
78
††
10 to 10
fibers/L
50,000/L min.
11 NTU ± 10%
0.002 ± 10%
0.015 mg/L ± 10%
1.8 mg/L ± 10%
2.1 mg/L ± 10%
0.210 mg/L ± 10%
0.210 mg/L ± 10%
2.0 mg/L ± 10%
3.0 mg/L ± 10%
0.006 mg/L ± 10%
200 ± 20%
140 ± 20%
140 ± 20%
140 ± 20%
1400 ± 20%
1400 ± 20%
200 ± 20%
140 ± 20%
2000 ± 20%
Maximum Permissable Product
Water Concentration
50% reduction
85% reduction
Maximum Permissable
Product Water Concentration
0.010 mg/L
0.005 mg/L
0.075 mg/L
0.040 mg/L
0.003 mg/L
0.003 mg/L
99%
99.95%
0.5 NTU
0.0002 mg/L
0.005 mg/L
0.60 mg/L
0.70 mg/L
0.07 mg/L
0.07 mg/L
0.1 mg/L
1.0 mg/L
0.002 mg/L
60 ng/L
20 ng/L
20 ng/L
20 ng/L
200 ng/L
200 ng/L
30 ng/L
20 ng/L
300 ng/L
■ The water system must be installed in compliance with state and local
laws and regulations.
■ Do not use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used on disinfected waters
that may contain filterable cysts. EPA Est. No. 082047-TWN-001.
■ Refer to the "Warranty" section (in the User Instructions or User Guide)
for the Manufacturer's limited warranty, name and telephone number.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Average% Reduction
97.0%
>99.9%
Average% Reduction
>99.3% / 98.6%
96.0%
99.8%
91.9%
93.3%
92.4%
>99%
>99.99%
99.0%
98.9%
>96.6%
>99.8%
99.4%
>99.8%
93.8%
99.8%
87.9%
>96.6%
95.9%
>96.9%
>96.4%
>97.0%
>97.4%
>97.9%
93.8%
96.1%
99.20%
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.6 gpm (2.27 lpm) @ 60 psi

Publicité

Table des Matières
loading

Table des Matières