Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools needed
Pencil
#2 Phillips
screwdriver
Drill with ¹⁄₈" (3 mm), ¹⁄₂" (13 mm),
and 1¹⁄₄" (3 cm) bits
Parts supplied
Remove parts from package. Check that all parts are included.
#8-18 x 1"
(4.2 x 25 mm)
flat-head screws
Drywall
anchors
Parts needed
UL Listed/CSA
UL Listed/CSA
Approved ¹⁄₂" (13 mm)
Approved
strain relief
wire connectors
Optional accessories
Power
Charcoal
cord kit
filter kit
Part Number
Part Number
W10355452*
W10355450*
* For information on ordering, see the "Assistance or Service"
section.
4
INSTALLATION REQUIREMENTS
Wire stripper
Flat-blade
screwdriver
#8-18 x ⁵⁄₈"
(4.2 x 16 mm)
truss-head screws
Mounting
brackets
120V, 75W
maximum,
type E26
incandescent lamp
Stainless steel
cleaner and
polish
Part Number
31462A*
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
It is the installer's responsibility to comply with installation
■
clearances specified on the model/serial/rating plate.
The model/serial/rating plate is located inside the range
hood on the left wall.
Range hood location should be away from strong draft
■
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be
■
used. Given dimensions provide minimum clearance.
Consult the cooktop/range manufacturer installation
instructions before making any cutouts.
This range hood is recommended for use with cooktops
■
with a maximum total rating of 40,000 BTUs or less.
Grounded electrical outlet is required. See "Electrical
■
Requirements" section.
All openings in ceiling and wall where range hood will
■
be installed must be sealed.
These range hoods are factory set for non-vented
■
installations and require charcoal filters. See the
"Assistance or Service" section for information
on ordering charcoal filters.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, title 24, HUD, Part 280)
or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
2"
(5.1 cm)
4¹⁵⁄₁₆"
⁷⁄₈"
(12.5 cm)
(2.2 cm)
29¹⁵⁄₁₆" (76.0 cm) or
35¹⁵⁄₁₆" (91.0 cm)
6⁹⁄₁₆" (16.7 cm) or
9⁹⁄₁₆" (24.4 cm)
9"
(22.9 cm)
1¹⁄₂"
18⁵⁄₈"
(3.8 cm)
(47.3 cm)
1"
(2.5 cm)