Insulation; Gas Connection; Placing The Concentric Channel System; Instructions For Placing The Outflow - WANDERS Balsa 75 Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The Balsa must not be built into the wall, and must be placed on a fl oor that is solid enough to hold the
appliance. The distance from the Balsa to the rear wall must be at least 10 cm, and there must be a free space
of at least 80 centimetres to the right and left side of the fi replace. Be sure to place the Balsa on a solid fl oor
plumb under the fl ue pipe.

Insulation

Due to the high temperatures of the exterior walls (up to approximately 150 °C or 300 °F) it is prohibited to
have or to place any combustible materials close to the channel system. The entire concentric pipe system
should be encased with fi reproof material from the place where it is out of sight up to the outlet in the exterior
wall. Ventilate the encased concentric pipe system by placing a grate near the fl oor and the ceiling on every
fl oor. Use universal wall clips with a diameter of 150 mm for anchoring the concentric pipe system.
!
Do not insulate the concentric channel
If an existing chimney is used, fi rst make sure whether the chimney is suffi ciently insulated and is wide
enough to accommodate the concentric pipe system. If the chimney was previously used as a wood-burning
or coal-fi red stove, it must fi rst be professionally cleaned. You must use special WANDERS connecting sets for
connecting a gas hearth to an existing chimney.

Gas connection

Use a feed pipe with an approved G3/8" stop cock with coupling.
De-aerate the supply pipe before fi tting and fastening the appliance.
Avoid tension on the operating valve and pipes to avoid gas leakage.
Check if the connection is gastight.

Placing the concentric channel system

The appliance is approved according to the European CE regulations for gas appliances with the WANDERS
concentric fl ue systems (Ø 100 / 150 mm) and are to used only in that combination. The warranty will be partly
or entirely invalid if another system is used during installation. The WANDERS concentric system (Ø 100 / 150
mm) can be used with existing situations or newly built situations.
Instructions for placing the outfl ow
The outfl ow of the pipe system can be placed on top of the roof or against the side
wall of the house.
Outfl ow on top of the roof
When placing the outfl ow on top of the roof, make sure that there is a distance of at
least 50 cm between the outfl ow and the edges of the roof, with the exception of a
possible existing ridge. You must also take the place of the outfl ow into account in
relation to the existing ventilation openings, movable windows and combustion air
supply provisions. Please consult the national and local requirements.
Outfl ow into the wall
When placing the outfl ow into the side wall, make sure that there is distance of at least
50 cm between the outfl ow and the corners of the building, eaves, gutters, balconies
and etceteras. You need not have this distance when the outfl ow runs to at least the
front side of the overhanging part.
24
Min.
50 cm

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Balsa 100

Table des Matières