B
min 5 mm
(max 150 mm)
60 mm
Technical data
Hob dimensions
Width
Depth
Bypass diameters
BURNER
Triple Crown
Semi-rapid
Auxiliary
Other technical data
TOTAL POWER:
Electric supply:
Appliance category:
Gas connection:
Appliance class:
Gas burners for NATURAL GAS G20 20 mbar
BURNER
Triple Crown
Semi-rapid
Auxiliary
14
A
min 30 mm
56
32
28
Gas original:
Gas replacement:
220-240 V ~ 50/60 Hz
II2H3+
G 1/2"
3
NORMAL POWER kW
4,0
2,0
1,0
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and the
oven must be installed separately for safety
reasons and to let easy remove oven from the
unit.
594 mm
510 mm
Ø BYPASS 1/100 mm
G20 (2H) 20 mbar = 9 kW
G30 (3+) 28-30 mbar = 654 g/h
G31 (3+) 37 mbar = 643 g/h
MINIMUM POWER kW
1,4
0,45
0,33
INJECTOR MARK
1/100 mm
146
96
70
www.zanussi.com