If an inverter shutdown was preceded by a buzzing sound, there may
ƒ
be an excessive load in combination with a low voltage or cable
problem.
Normal operating range is 11V to 15V DC.
ƒ
AC Outlets — These outlets can supply up to 15 amps at 115V AC 60 Hz
High Output AC Terminals — There are three insulated terminals on the
front panel of the inverter. These terminals are for connecting 115 volt AC
devices that require more than 15 amps to operate. Other uses are for
connection to distributed wiring that has multiple AC outlets. Remove 2
screws on protective cover to access terminals. Any AC output wiring that
is directly connected must comply with US National Electric Code (NEC)
wiring gauge recommendations. Facing the front panel, the terminals are:
Left
Neutral
NEUTRAL and GROUND are bonded inside the inverter to comply with the
National Electric Code (NEC) requirement that any AC source must have a
neutral to ground connection.
USB Power Port — This power port can supply 5 volts at 2.1A for charging
or powering tablets, e-readers, smartphones, and other small electronic
devices.
Audible Alarm (internal to the inverter) — When the Audible Alarm makes
a buzzing sound, the inverter senses a low battery condition. The user
should reduce the AC load, charge the battery, and check the DC cable for
excessive losses.
Remote Switch Connection
5
®
Middle
Ground
www.wagan.com
Right
Live