Wagan Tech PURE LINE 3000 Guide D'utilisation page 14

Masquer les pouces Voir aussi pour PURE LINE 3000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pure Line 3000 by Wagan Tech
make the positive terminal connection immediately after the batteries have
been charging. Allow time for the battery gasses to vent to outside air.
9. Attach the positive cable to the Positive DC connector on the battery and
then the inverter. Make sure the connections are tight and secure.
10. Turn on the inverter from the Front Panel Power Switch "|"
11. Make certain that the green Operating LED is lit and the FAULT LED
indicator is not lit.
12. Turn Off "O" the inverter. The Fault LED may briefly "flash". This is normal.
The audible alarm may also sound a short "chirp". This is also normal.
13. When you have confirmed that the appliance to be operated is turned off,
plug the appliance into one of the two AC outlets on the front panel of the
inverter.
14. Turn the inverter on.
15. Turn the appliance on. The appliance should begin working.
16. Observe the LED indicators for normal operation.
Note: If an extension cord is used from the inverter to the appliance, limit the
extension cord length to 100 feet or less. Make sure that the cord is safety
approved and AWG 14 or greater to carry the appliance load. Remember that
extension cords are for temporary use.
13
®
www.wagan.com

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

3810

Table des Matières