10 - CONTROL
5 - Start-up/shutdown
button and LED indicator
If unit is standby, press, then unit will be OFF.
If unit is ON, press, then unit will be OFF.
If unit is OFF, press, then unit will be ON.
LED indicator will be lightened if unit is ON or standby and extinguished if unit is OFF.
6 - Decrease/down
If screen is unlocked, corresponding value will decrease by pushing
When setting temperature, press more than 1sec, temperature value will be decreased continuously.
When Setting clock/timer, press more than 1sec, Clock/timer value will be decreased continuously.
When setting vacation days, press more than 1sec, day value will be decreased continuously.
Under query mode, check items will page down by pressing.
7 - ENTER (Confirm/unlock)
If screen and buttons are unlocked, press to upload setting parameters after setting any parameter:
● If press within 10sec, setting parameters will be uploaded to unit;
● If press beyond 10sec, please resetting all parameters.
If screen and buttons are locked, press for 3sec. to unlock them.
8 - DISINFECT (anti-legionella)
Manually turn on disinfect function
Press
Icon will flash.
Confirm manually activate disinfection function .
The unit will heat up water to 65°C at least for disinfection.
Disinfect Clock Setting
Press for 3sec., to enter Disinfect clock setting.
40