6 - WATER CONNECTIONS
6.7 - HYDRAULIC CONNECTIONS
A
DHW outlet
B
DWH recirculation (only version 190S- 300S )
C
Solar outlet (only version 190S - 300S)
D
Solar inlet (only version 190S - 300S)
E
Aqueduct inlet
Connecting drains
F
G
L
I
F
Upper condensate outlet ø 10
G
Condensate drain ø 10
H
Domestic hot water safety valve
I
Storage tank discharge
L
Drain accumulation / drain pit
The condensate must be disposed in order to avoid damages
to people and things.
To smoothly drain condensate, the unit should be installed at a
horizontal floor. Otherwise, the drain vent is ensured at the
lowest place.
Recommending the inclination angle of unit to the ground
should be no more than 2°.
Condensate drain lines installed and piped to an adequate
drain accumulation /drain pit.
Arrange the drain pipe to ensure smooth draining.
Improper drainage work may cause wetting of the building,
furniture etc..
IMPORTANT: Water coming from the plastic shroud is an
indicator that both condensation drain lines (F - G) may be
blocked
Immediate action is required.
A discharge pipe connected to the pressure-relief (H) device is
to be installed in a continuously downward direction and in a
frost-free environment.
H
Condensate drain
19