Hydraulic System - Airwell AWHM-TDF 190 Manuel D'installation, D'utilisation Et D'entretien

Pour la production d'eau chaude sanitaire
Masquer les pouces Voir aussi pour AWHM-TDF 190:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1 - GENERAL INSTRUCTIONS
and domestic hot water, within limits
defined in the technical bulletin and on
this manual.
Any use other than intended does not
involve the manufacturer in any
commitment or obligation.

HYDRAULIC SYSTEM

Components
Selection and installation of system
components must be carry out by
installer.
Water quality
The water quality is determined by the
following factors, avoid therefore:
- Inorganic salts
- pH
- Biological load (seaweeds etc)
- Suspended solids
- Dissolved oxygen
Water with inadequate characteristics
can cause:
- pressure drop increase
- energy efficiency decrease
- corrosive symptom increase
Risk of freeze
If the unit or the relative water
connections can be subject to
temperatures close to 0°C adopt
measures for prevent risk of freeze.
The appliance is intended to be
permanently connected to the water
mains and not connected by a hose-set .
The water may drip from the discharge
pipe of the pressure-relief device and
that this pipe must be left open to the
atmosphere.
The pressure-relief device is to be
operated regularly to remove lime
deposits and to verify that is not blocked.
A discharge pipe connected to the
pressure-relief device is to be installed in
a continuously downward direction and
in a frost-free environment.
ELETTRIC SYSTEM
This unit is required reliable earthing
before usage, otherwise might cause
death or injury.
General
The characteristics of the electrical lines
must be determined by specialized
personnel able to design electrical
installations; moreover, the lines must be
in conformity with regulations in force.
Operate in compliance with safety
regulations in force .
This unit is required reliable earthing
before usage, otherwise might cause
death or injury.
If you can't make sure that your house
power supply is earthed well, please
don't install the unit if it does not in
conformity with regulations in force.
The power supply should be an
independent circuit with rated voltage.
Power supply circuit should be earthed
effectively.
Do not use water pipes to earthing
connection of the unit
Use single protection devices : gloves,
glasses ecc.
The power cables and the protection
cable section must be defined in
accordance with the characteristics of the
protections adopted. The serial number
label reports the unit specific electrical
data, included any electrical accessories.
Connection
All electrical operations should be
performed by trained personnel having
the necessary requirements by the
regulations in force and being informed
about the risks relevant to these
activities. Refer to the unit electrical
diagram (the number of the diagram is
6

Hide quick links:

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Awhm-tdf 300

Table des Matières