4 - 5
STOP
4 - 6
OPEN/CLOSE
4 - 7
PEDESTRIAN
RX
8 - 9
PHOTOCELLS
TX
10 - 11
PHOTOCELL
FLASHING
12 - 13
LIGHT
GATE OPEN
14 - 15
LED
16 - 17
2
RADIO CH
nd
18 - 19
AERIAL
18V DC
20 - 21
MOTOR
M5
ENCODER
22 - 23
BATTERY
5. MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing
the adjustment operations.
The gate must be equipped with the opening and closing safety stops.
When you have completed the installation procedures :
1_ bring the gate to approx. 1 m from the closing travel limit;
2_ set dip-switch no. 10 to ON;
3_ operate the automation using one of the following inputs: A/C, radio control or card button (PROG);
4_ the gate must start to close.
If it opens, stop the programming procedure by resetting the electric panel (disconnect
the power supply to the panel for at least 5 sec. and set dip-switch no. 10 to OFF); with
the control panel disconnected, exchange the motor supply wires. Restart the proce-
dure from point 1.
STOP pushbutton input (Normally Closed contact); It stops the gate in any
position, temporarily inhibiting its automatic closing, if programmed. 4=
COMMON, 5= STOP.
NOTE: A safety micro-switch is connected to the STOP push-button. In
case the STOP input remains open for more than 5 seconds, the opera-
tor will perform a cycle at a slow speed to reset the operating param-
eters to the values originally saved (see "Restoring automatic opera-
tion"). The micro-switch should be connected in series to further STOP
push-buttons where present.
OPEN/CLOSE pushbutton input (Normally Open contact); It commands the
opening and closing of the gate and its operation is controlled by dip-switch-
es 2 and 4. 5= OPEN/CLOSE.
PEDESTRIAN pushbutton input (Normally Open contact); It commands the
partial opening and closing of the gate for ~1 m of travel and its operation is
controlled by dip-switches 2 and 4.
7= PEDESTRIAN.
18 Vdc, max. 15 W, output to POWER THE RXs AND ANY OTHER TXs OF PHO-
TOCELLS THAT ARE PRESENT, EXTERNAL RECEIVERS, etc.; connect a max. of
3 pair of photocells.
8= NEGATIVE, 9= POSITIVE.
18 Vdc, output for PHOTOCELL TX (only the one that performs the Pho-
totest) max. no. 1 photocell transmitter.
10= NEGATIVE, 11= POSITIVE.
FLASHING LIGHT output 18 Vdc, max. 20 W. The signal is already modulated
for direct use. Flashing frequency during closing is double. 12= NEGATIVE,
13= POSITIVE.
GATE OPEN LED output 18 Vdc, max. 3 W; during opening of the gate the
warning light flashes slowly, when the gate is open it remains steadily illumi-
nated and during closure it flashes twice as fast. 14= NEGATIVE, 15= POSITIVE.
2nd RADIO CHANNEL output (its operation depends on dip-switches nos. 7 -
8) to be used for opening/closing another gate, for controlling garden lights
or for the "ZONE LIGHTING" function.
Warning: to connect other devices to the 2nd Radio Channel (area
lighting, pumps, etc.), use an additional auxiliary relay.
433,92 MHz built-in RX ANTENNA input.
18= EARTH, 19= SIGNAL.
MOTOR supply output 18 Vdc, max. 50 W.
20= NEGATIVE, 21= POSITIVE.
quick coupling for ENCODER connection.
Blue= 0 Vdc (GND), brown= 5 Vdc (+5V),
white= ENCODER SIGNAL (ENC).
BATTERY 12V - 7,2Ah input.
16