Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Raindance AIR 26601000 Mode D'emploi / Instructions De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
• The mesh washer must be insert to protect the over-
head shower against incoming dirt by pipework. In-
coming dirt leads to defects or/and can damage parts
of the shower; such caused faults voids all liability and
guarantee claims.
4
English
Wall mount see page 32
Ceiling mount see page 31

Technical Data

Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 34)

Flow diagram

(see page 34)
Operation (see page 41)
To empty the overhead shower after use,
hold it in a slightly inclined position.
Cleaning (see page 38) and en-
closed brochure
Spare parts (see page 40)
Test certificate (see page 44)
max. 0,6 MPa
0,1 - 0,4 MPa
max. 60°C
max. 70°C / 4 min

Publicité

Table des Matières
loading

Table des Matières