38 | English
External dust extraction (see figure k)
– Firmly insert a suitable dust extraction hose into the dust
extraction adapter (29).
The dust extractor must be suitable for the material being
worked.
When extracting dry dust that is especially detrimental to
health or carcinogenic, use a special dust extractor.
Changing the saw blade (see figures l1−l4)
Pull the plug out of the socket before carrying out any
u
work on the power tool.
When mounting the saw blade, wear protective
u
gloves. This poses a risk of injury.
Only use saw blades the maximum permitted speed of
u
which is higher than the no-load speed of the power
tool.
Only use saw blades that match the specifications
u
given in this operating manual and that are tested and
marked in accordance with EN 847-1
Only use saw blades that are recommended by the
u
power tool manufacturer and are suitable for use on
the material you want to saw. This prevents the saw
tooth tips from overheating and the plastic you want to
saw from melting.
Do not use HSS saw blades. Such saw blades can easily
u
break.
Removing the saw blade
– Open the clamping lever (36) and pull the protective
cover (3) out of the groove on the riving knife (4).
– Turn the locking screw (35) as far as possible in the "Un-
lock" direction using the tip of the ring spanner (9) and lift
the table insert (23) out of the tool chamber. A gripping
hole (45) is integrated into the tool for ease of lifting.
– Turn the crank (15) clockwise as far as possible so that
the saw blade (24) is in the highest possible position
above the saw table.
– Turn the clamping nut (46) using the ring spanner (9)
while pulling the spindle locking lever (47) until it en-
gages.
– Keep pulling the spindle locking lever and unscrew the
clamping nut anticlockwise.
– Remove the clamping flange (48).
– Remove the saw blade (24).
Fitting the saw blade
If necessary, clean all the parts you want to fit before in-
stalling them.
– Place the new saw blade on the mounting flange (49) of
the tool spindle (50).
Note: Use sufficiently large saw blades. The radial clearance
between the saw blade and the riving knife must not exceed
3−8 mm (max.).
When fitting the saw blade, make sure that the cutting
u
direction of the teeth (direction of the arrow on the
1 609 92A 4PA | (01.03.2019)
saw blade) matches the direction of the arrow on the
riving knife.
– Fit the clamping flange (48) and the clamping nut (46).
– Turn the clamping nut (46) using the ring spanner (9)
while pulling the spindle locking lever (47) until it en-
gages.
– Tighten the clamping nut by turning it clockwise.
– Place the table insert (23) over the riving knife (4) and
into the tool chamber. Turn the locking screw (35) as far
as possible in the "Lock" direction using the tip of the ring
spanner (9).
– Refit the protective cover (3) (see "Fitting the protective
cover (see figures d1–d2)", page 36).
Operation
Pull the plug out of the socket before carrying out any
u
work on the power tool.
Transport position and work position of the saw
blade
Transport position
– Remove the protective cover (3), remove the table insert
(23) and place the riving knife (4) in the bottom position.
Reinsert the table insert (23).
– Turn the crank (15) anticlockwise until the teeth of the
saw blade (24) lie below the saw table (21).
– Push the saw table expansion (6) in fully.
Push the clamping handle (13) down. This fixes the saw
table expansion in place.
Work position
– Position the riving knife (4) in the top position directly
over the centre of the saw blade, insert the table insert
(23) and fit the protective cover (3).
– Turn the crank (15) clockwise until the top teeth of the
saw blade (24) are approx. 3−6 mm above the work-
piece.
Extending the saw table
The free end of long and heavy workpieces must have some-
thing placed underneath it or be supported.
Saw table expansion (see figure A)
The saw table expansion (6) increases the width of the saw
table (21) on the right.
– Pull the clamping handle (13) for the saw table expansion
all the way up.
– Pull out the saw table expansion (6) to the required
length.
– Push the clamping handle (13) down. This fixes the saw
table expansion in place.
Bosch Power Tools