3. Technical data and use in accordance with intended use
Operating Temperature
Ambient: -20 ... +60 °C
Attention: Footnote 1) under table 1 must be absolutely taken into account!
GB
Medium: see table 1
Attention! With gaseous substances the temperature may increase as a result
of the compression temperature. In such cases the pressure change rate has to
be slowed down resp. the permissible medium temperature has to be reduced.
Table 1: Permissible medium temperature (only mechanical part)
Ignition temperature of
the ambient atmosphere
(temperature class)
> 85 °C
(T 6)
> 100 °C (T 5)
> 135 °C (T 4)
> 200 °C (T 3)
> 300 °C (T 2)
> 450 °C (T 1)
1) The permissible uppper ambient temperature for the electrical components is determined by the
electrical connection values and the ignition temperature of the ambient gases, vapours and dusts.
Therefore the maximum permissible ambient temperatures specified in the EC-type examination
certificates for slot-type sensors and SN sensors must be observed as well. The lower of these two
values is to be considered the maximum permissible ambient temperature!
Materials (wetted parts)
Part
Pressure connection
Capsule element
Sealing ring
(connection/capsule)
6
WIKA Operating instructions pressure gauges Model 6 with 831 per ATEX
Permissible maximum medium temperature
(in the pressure system)
+70 °C
+85 °C
+100 °C
+100 °C
+100 °C
+100 °C
Model 612.20 Model 63X.50
Cu-alloy
stainless steel
Cu-alloy
stainless steel
NBR
FPM
(Buna rubber)
(Viton)
Model 614.11 Model 634.11
Cu-alloy
stainless steel
Cu-alloy
stainless steel
NBR
FPM
(Buna rubber)
(Viton)