Overload Protection - Amprobe 5XP-A Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

5XP-A Electrical Specifications
(at 23°C ± 5°C, < 75 % R.H.)
DC VOLTS
Ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
Accuracy: ± (1.0 % rdg + 1 dgt)
AC VOLTS (45 Hz to 500 Hz)
Ranges: 200 mV, 2 V, 20 V, 200 V, 600 V
Accuracy: ± (1.5 % rdg + 5 dgts)
DC CURRENT
Ranges: 200 µA, 2 mA, 20 mA, 200 mA,
± (1.5 % rdg + 1 dgt)
AC CURRENT (45 Hz to 500 Hz)
Ranges: 200 µA, 2 mA, 20 mA, 200 mA,
± (2.0 % rdg + 5 dgts)
RESISTANCE
Ranges: 200 , 2 k, 20 k, 200 k, 2 M, 20 M
Accuracy: ± (1.0 % rdg + 4 dgts) on 200 to 200 k
ranges: ± (1.5 % rdg + 4 dgts) on 2 M range: ± (3.0 % rdg +
5 dgts) on 20 M range
CONTINUITY
Audible indication: 75 ± 25 
DIODE TEST
Test current: 1.0 mA (approximate)
Accuracy: ± (1.5 % rdg + 3 dgts)
Open circuit volts: 3.0 dc typical
BATTERY TEST
Ranges: 1.5 V, 9 V
Accuracy: ± (3.5 % rdg + 2 dgts)

OVERLOAD PROTECTION

Voltage, Resistance, Diode, Continuity:
600 VDC or 600 VAC rms
200 mV Range: 600 VDC / 600 VAC rms (3 minutes)
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

15xp-b35xp-a15xp-a

Table des Matières