• Disconnect the charger from the outlet before attempting
any cleaning. This will reduce the risk of electric shock.
Removing the battery pack will not reduce this risk.
• NEVER attempt to connect 2 chargers together.
• The charger is designed to operate on standard 120V
household electrical power. Do not attempt to use it on any
other voltage. This does not apply to the vehicular charger.
Chargers
Your tool uses a D
WALT charger. Be sure to read all safety instructions
E
before using your charger. Consult the chart on the back cover of this
manual for compatibility of chargers and battery packs.
Charging Procedure (Fig. 1)
1. Plug the charger into an
FIG. 1
appropriate
outlet
before inserting battery
pack.
2. Insert the battery pack
(F) into the charger,
as shown in Figure 1,
making sure the pack
is fully seated in charger.
The red (charging) light
will blink continuously
indicating
that
the
charging process has
started.
3. The completion of charge will be indicated by the red light
remaining ON continuously. The pack is fully charged and may be
used at this time or left in the charger.
Indicator Light Operation
DCB106
PACK CHARGING
PACK CHARGED
DCB107, DCB112
PACK CHARGING
PACK CHARGED
HOT/COLD DELAY
Charge Indicators
F
HOT/COLD PACK DELAY
DCB107, DCB112
The DCB107 and DCB112 chargers have a hot/cold delay feature.
When the charger detects a battery that is hot, it automatically delays
charging until the battery has cooled. When the charger detects a
battery that is cold, it automatically delays charging until the battery
has warmed.
The red light will continue to blink, but a yellow indicator light will be
illuminated during this operation. Once the battery has cooled, the
yellow light will turn off and the charger will resume the charging
procedure.
LEAVING THE BATTERY PACK IN THE CHARGER
The charger and battery pack can be left connected with the charge
indicator showing Pack Charged.
7