Storage
Store protected from direct sunlight, at -10...+30 °C and relative humidity (RH) under 75 % (sealed filters
RH max. 95 %).
Interim recharging
Deep discharge of the battery during long-term storage can be prevented by keeping the blower device on
recharge.
However, if standby charging is unpractical, batteries can be interim-recharged e.g. three times a year. Prior
to use, at least one cycle of discharge and charge should be carried out.
Disposal
See WEEE.
A very contaminated blower device as well as used filters are special refuse and shall be disposed of
according to the filtered substances (gases or particles).
Discarded batteries are hazardous waste. Make sure that they are disposed of according to waste
treatment regulations.
8. Maintenance
The blower device shall be serviced at least once a year by a Service Center authorized by Scott (http://
www.scottsafety.com).
Replace worn-out filters. Always replace all filters at the same time.
Check that the breathing hose is undamaged and replace a broken one. Replace other parts when
necessary.
Only use original spare parts.
Maintenance of the facepieces is described in the respective Instructions for Use.
Australia and New Zealand:
For complete national requirements, please refer to the standard AS/NZS1715:2009, Use & Maintenance
of Respiratory Products.
Note!
o
Clogged filters increase motor load and shorten the motor life.
o
The battery's capacity is reduced over time. Deterioration is accelerated by storage in a warm place.
Replacing the battery (àsee picture series)
1
Detach breathing hose.
2
Detach body tensioner.
3
Remove blower from its body by turning it towards yourself with your fingertips (using your thumb to
grip the blower).
4-6
Carefully take hold of the battery leads and pull the battery out of the blower body. Open the connector
and change the battery. (The rubber band included with the battery will secure the connector in the
proper position.) Reattach the connector. Press the battery in to its base.
7
Insert the blower's thread into the body opening and, using your fingers, guide the leads toward the
battery space (the leads must not be left at the air channel in the middle of the blower body).
8-9
When the blower's thread is slightly visible in the body opening, press the blower into place with the
palm of your hand. Center the blower's thread in the body opening.
10-12 Position the body tensioner. Screw the detached thread ring tightly on the blower's thread to make the
body tensioner fit correctly and to make it easy to screw the heads to each other. Leave a space of
3–5 mm between the heads. (Make sure that the blower's thread is properly centered in the body
tensioner's opening.) Remove the thread ring.
13
Charge the battery.