sigfox Pulse - Guide utilisateur / User guide version V2.0.0
•
Bytes 9 to 10 : Delta B1 : index variation of channel B during the time interval between 20 to 30 minutes after transmitting the previous
frame.
In the example in grey this gives:
•
Byte 2: frame index: index of this frame in a multi-message sequence (always null in this configuration) = 1 (second frame)
•
Bytes 3 to 4 : Delta A0 : index variation of channel A during the time interval between 10 to 20 minutes after transmitting the previous
frame = 0x0012 so 18 additional pulses
•
Bytes 5 to 6 : Delta B0 : index variation of channel B during the time interval between 10 to 20 minutes after transmitting the previous
FR
frame = 0x0020 so 32 additional pulses
•
Bytes 7 to 8 : Delta A1 : index variation of channel A during the time interval between 20 to 30 minutes after transmitting the previous
frame = 0x0007 so 7 additional pulses
•
Bytes 9 to 10 : Delta B1 : index variation of channel B during the time interval between 20 to 30 minutes after transmitting the previous
frame = 0x0010 so 16 additional pulses
Frame 3/4 :
EN
0
Code
0x48
Cf Status
0x48
Description of the frame:
•
Byte 2: frame index: index of this frame in a multi-message sequence
•
Bytes 3 to 4 : Delta A2 : index variation of channel A during the time interval between 30 to 40 minutes after transmitting the previous
frame.
•
Bytes 5 to 6 : Delta B2 : index variation of channel B during the time interval between 30 to 40 minutes after transmitting the previous
frame.
•
Bytes 7 to 8 : Delta A3 : index variation of channel A during the time interval between 40 to 50 minutes after transmitting the previous
frame.
•
Bytes 9 to 10 : Delta B3 : index variation of channel B during the time interval between 40 to 50 minutes after transmitting the previous
frame.
In the example in grey this gives:
•
Byte 2: frame index: index of this frame in a multi-message sequence (always null in this configuration) = 2 (third frame)
•
Bytes 3 to 4 : Delta A2 : index variation of channel A during the time interval between 30 to 40 minutes after transmitting the previous
frame = 0x0100 so 256 additional pulses
•
Bytes 5 to 6 : Delta B2 : index variation of channel B during the time interval between 30 to 40 minutes after transmitting the previous
frame = 0x00F0 so 240 additional pulses
•
Bytes 7 to 8 : Delta A3 : index variation of channel A during the time interval between 40 to 50 minutes after transmitting the previous
frame = 0x0000 so aucune pulses
•
Bytes 9 to 10 : Delta B3 : index variation of channel B during the time interval between 40 to 50 minutes after transmitting the previous
frame = 0x0015 so 21 additional pulses
Frame 4/4 :
0
Code
Status
0x48
Cf Status
0x48
0xA3
Description of the frame:
•
Byte 2: frame index: index of this frame in a multi-message sequence
•
Bytes 3 to 4 : Delta A4 : index variation of channel A during the time interval between 50 to 60 minutes after transmitting the previous
frame.
•
Bytes 5 to 6 : Delta B4 : index variation of channel B during the time interval between 50 to 60 minutes after transmitting the previous
frame.
1
2
Status
Frame index
0xA3
2
1
2
PAYLOAD...
Frame index
Delta A4
3
0x074A
3 to 4
5 to 6
PAYLOAD...
Delta A2
Delta B2
0x0100
0x00F0
3 to 4
5 to 6
Delta B4
0x003B
7 to 8
9 to 10
Delta A3
Delta B3
0x0000
0x00015
Page
82