sigfox Pulse - Guide utilisateur / User guide version V2.0.0
320
1
FR
EN
321
1
322
1
Configuration of the internal
sensor (A et B)
History configuration (chan-
nels A and B)
Anti-bounce filter period
(pulse minimum width)
(channels A and B)
Hexadecimal
Default value: 0x11
For channel A :
•
Bit 0 : channel A activation
• Value 0: channel deactivated
• Value 1: channel activated
•
Bit 1 : meter type channel A (pull-up activation)
• Value 0: meter other than Gas (pull-up deactivated)
• Value 1: Gas meter (pull-up activated)
•
Bit 2 : Reserved
•
Bit 3 : tamper input channel A
• Value 0: deactivated
• Value 1: activated
For channel B :
•
Bit 0 : channel B activation
• Value 0: channel deactivated
• Value 1: channel activated
•
Bit 1 : meter type channel B (pull-up activation)
• Value 0: meter other than Gas (pull-up deactivated)
• Value 1: Gas meter (pull-up activated)
•
Bit 2 : Reserved
•
Bit 3 : tamper input channel B
• Value 0: deactivated
• Value 1: activated
Hexadecimal
Default value : 0x00
Bits 0 to 2: History configuration
•
Value 0: no history
•
Value 1: history period set to 10min / transmit period set
to 1 hour
•
Value 2: history period set to 1 hour / transmit period set
to 24 hours
Hexadecimal
Default value: 0x22
Bits 0 to 3 : anti-bounce filter period - channel A
•
Value 0: desactived
•
Value 1: 1 ms
•
Value 2: 10 ms
•
Value 3: 20 ms
•
Value 4: 50 ms
•
Value 5: 100 ms
•
Value 6: 200 ms
•
Value 7: 500 ms
•
Value 8: 1 s
•
Value 9: 2 s
•
Value A: 5 s
•
Value B: 10 s
•
Value C à F : reserved
Bits 4 to 7 : anti-bounce filter period - channel B
•
Value 0: désactivé
•
Value 1: 1 ms
•
Value 2: 10 ms
•
Value 3: 20 ms
•
Value 4: 50 ms
•
Value 5: 100 ms
•
Value 6: 200 ms
•
Value 7: 500 ms
•
Value 8: 1 s
•
Value 9: 2 s
•
Value A: 5 s
•
Value B: 10 s
•
Value C à F : reserved
Page