The required
temperature is not
reached
ERROR CODES
N°
Code
1
EE 1
2
EE 2
3
EE 3
4
EE 4
5
PP 1
6
PP 2
7
PP 3
8
PP 4
9
PP 5
10
PP 6
11
PP 7
888/EE8/Other
12
messy codes
Caution! Do not dismantle or repair the pool heat pump yourself, contact your dealer !
NOTPACBYAQUALUX - ind H - 02/15
No voltage
Circuit breaker tripped
Blocked air inlet
Blocked air outlet
Three-minute defrost
Temperature setting too low
Has not been operating for
long enough
Actual application is different
from the application used in
the cost estimate
Description of the fault
High-pressure protection
Low-pressure protection
Flow rate controller
Phase order (three-phase machines only)
Pool temperature sensor (water exchanger)
Condensation temperature sensor (water exchanger)
Pressure relief temperature sensor (air exchanger)
Suction temperature sensor (compressor)
Air temperature sensor (air exchanger)
Compressor overload
Low temperature (water or air) < 0°C, automatic reset
Signal communication failure between PCB and control panel
Look for the cause and reset the
protective devices
Look for the cause and reset the circuit
breaker
Clean the air inlet
Clean the air outlet
Please wait
Increase the temperature setting
Increase the filter time and the operating
range of the heat pump.
Check and change the
settings (cover time, required
temperature, period of use, etc.)
18 /38