AQUALUX 104269 Notice D'installation Et D'utilisation page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Non-contractual scheme, pool water input / output water on back side
Dim (mm)
A
104269
234
104272
234
104273
234
105535
234
105536
234
105537
312
LIST OF ITEMS SUPPLIED
1 heat pump with integrated control panel + 2 fittings + condensate drain kit
-
1 manual
-
STEPS IN THE INSTALLATION PROCESS
Position
- The heat pump must be installed OUSTSIDE in a well ventilated place, far from any sources of
combustibles. In order to reduce noise levels :
- Do not direct ventilation towards neighboring
- Avoid corners and courtyards that increase the reflection of sound transmitted and received
(eg against a wall: + 3 dB (A) in a corner: + 6 dB (A), in a courtyard: + 9 dB (A))
- Install the CAP away from property lines and comply with the established rules private property
- Do not install under windows
Refer to national laws regarding the struggle against neighborhood noise
The water pipe between the pool and the heat pump must not exceed 10m.Provide for the discharge by
gravity of condensates under the machine. For maintenance reasons, the pump must not be placed in an
area where vegetation is present (leaves, pine needles, etc.).
Ideally, the heat pump should be protected against outdoor phenomena (rain, snow, etc.) by a shelter.
NOTPACBYAQUALUX - ind H - 02/15
B
C
429
312
429
312
429
312
590
312
590
312
590
392
Heatpump
pummpe
Technical room
Pool
D
E
278
800
278
800
278
800
278
961
278
961
357
961
13 /38
F
G
250
76
250
76
220
76
280
77
320
77
310
77
50 cm mini
H
558
558
558
658
658
658