CANCELLING THE AUTOMATIC MODE
- Press
and
- When the number flashes, press the button to set the time
- When the light goes off and the display shows the temperature of the water, the automatic Time On
and Time Off modes are cancelled.
- After 30 seconds, the display stops flashing.
CHECKS - TESTS
- Check the connections of the water pipes.
- Check the position of the valves.
- Check the electric connection and test the 30mA differential protective device.
- Check that the air inlet and outlet are not obstructed.
- Switch on the filter pump (or the auxiliary pump) used to deliver the required water flow in the heat
pump.
- Check for leaks.
- Set the required temperature on the thermostat.
- Use the On/Off switch to switch on the heat pump.
- The compressor starts one minute after the fan.
- Once the machine is running, check for any unusual noises.
MAINTENANCE
machine!!
Wintering
- Disconnect the power supply and drain any water inside the machine by unscrewing the couplings and
pump up remaining water inside exchanger if necessary.
- Cover the machine with protective film.
SEASONAL TASKS
Stop the heat pump
Visually check the attachment and the hydraulic
and electrical connections
Check the discharge of condensates
Clean air grids
Check the cut-off devices and the settings of the
digital control panel
Clean the cover with soapy water.
Do not use high-pressure jets or corrosive
products
FAQ
Observation
The heat pump
does not start
NOTPACBYAQUALUX - ind H - 02/15
TIME OFF
to cancel the Time On and Time Off modes.
!! Disconnect the power supply before working on the
Causes
No current
Stop button pressed
and the temperature of the water appears.
.
MINIMUM FREQUENCY
For all work on the filter valve
On every visit to the technical premises
Whenever the power supply is cut
Once a year
Measure the voltage. If 0 Volt wait for the
current to return
Press the button
17 /38
to set the
Solutions