Single-phase 230 V power supply
Neutral
- Connect the heat pump to a suitable electric power supply. The voltage must correspond to the
machine's nominal voltage.
- Connect the ground.
- Depending on the location, install any required lightning-proof devices.
- Protect the circuit with a suitable circuit breaker or fuse.
- The power cable and the signal cable must not come into contact. Otherwise interference with the
control signals may occur.
Special cases
In the event of an unexpected power cut, the heat pump automatically restarts. Check the
settings and adjust if necessary.
In the event of an expected power cut, switch off the heat pump. As soon as the power is
restored, switch on the pump, check the settings and adjust if necessary.
Always switch off the machine in stormy weather.
USE
Preparing the pool (first use)
- Fill the pool with mains water. Avoid using well water which may have variable and unknown
characteristics. If you cannot use mains water, use the BY AQUALUX anti-scaling metal control product
that will prevent any possible discomfort.
- Clean the pool, the skimmer and pump pre-filters and backwash the filter.
- If the sand in the filter is more than five years old, replace it or clean using a filter anti-scaling agent by
BY AQUALUX range.
- Adjust the pH to 7 – 7.4 using BY AQUALUX PH minus or BY AQUALUX PH plus.
- Add the BY AQUALUX anti-scaling agent.
- Proceed with shock treatment using BY AQUALUX liquid active oxygen (1 litre per 10m3).
Always observe the filtering times according to the temperature in order to save the disinfecting
products.
Always stop the pump before working on the filter valve and then switch it on again.
The chemical parameters of the water are maintained in the following ranges:
Acidity
Shock chlorine
Bromine
PHMB
Hardness
The swimming water is balanced according to the balance of Taylor.
DIGITAL CONTROL PANEL SETTINGS
NOTPACBYAQUALUX - ind H - 02/15
Circuit breaker or fuse (not supplied)
Ground
Phase
pH
7.00 – 7.80
ppm
max 5 for 24 hours
ppm
2 – 3
ppm
20 – 50
°F
10 – 50
Free chlorine
Salinity
Total alkali strength
15 /38
Heat pump control
PCB
ppm
1 – 3
g/l
0 – 5
°F
8 – 12