Make sure the tank lid has been closed safely before lifting
or transferring the appliance.
The appliance can easily be transferred by the handle and
drawn forward.
Troubleshooting
Failure
Possible
cause
Fan not
1. No power
starting and
supply
flame not
2. Engine
beginning to
winding is
burn.
burnt out or
broken
Fan starting
1. Ignition
and flame
system is not
not beginning
working.
to burn or
2. Flame
going out
control is
immediately.
faulty.
3. Photocell is
not working.
4. No or
insufficient
amount of oil
getting to the
burner.
5. Electric
valve is not
working.
Fan starting
1. Combustion
air is not
and flame
beginning to
sufficient.
burn but
2. The fuel
smoking.
used is dirty
or contains
water.
3. Air in the fuel
piping.
4. Oil volume in
the burner is
insufficient.
5. Too much oil
in the
burner.
Generator
1.
Electric
not pausing.
valve
sealing is
defective.
2.
Fan
thermostat
is
defective.
Flame
1. Insufficient
blasting off
air inlet in
the appliance
the
in the front.
combustion
chamber.
Removal
1.
Check the power
supply properties.
Check the switch
functionality and
position.
Check the safety fuse.
2.
Switch off the engine.
1.
Check the ignition
cabling to the
electrodes and
transformer. Check
the position of the
electrodes. Check
whether the electrodes
are clean. Replace the
ignition transformer.
2.
Replace the
appliance.
3.
Clean or replace the
photocell.
4.
Check the pump-
engine connection.
Check whether there
is air in the fuel piping.
Check the hoses and
filter sealing. Clean
the nozzle and replace
it if necessary.
5.
Check the plugging.
Clean the electric
valve and replace it if
necessary.
1.
Remove all possible
obstacles and
obstruction at the air
inlet or outlet. Check
the air inlet ring gauge
position. Clean the
screen.
2.
Replace the used oil
with fresh oil. Clean
the oil filter.
3.
Check the tightness of
hoses and the oil filter.
4.
Check the pump
pressure value. Clean
or replace the nozzle.
5.
Check the pump
pressure value.
Replace the nozzle.
1.
Replace the electric
valve body.
2.
Replace the fan
thermostat.
1.
Check the fan. Check
the air inlet.
Maintenance and storing
Keep the air slot and body with no dust and dirt.
For cleaning purposes, use a soft cloth and fine soap
solution. Prevent direct appliance contact with aggressive
cleaning agents. Aggressive, volatile and caustic cleaning
agents must not be used.
The appliance needs to be protected against moisture and
dust.
If the appliance is not used for a long time, store it in a
covered state in a dry, safe place inapproachable to
children.
Caution:
Do not service the appliance when plugged, being
operated or hot. The failure to do so could lead to
serious burns and electric shock.
Regular maintenance:
Part
Frequency
To be rinsed out every 150 – 200
Fuel tank (pic. F)
running hours or as needed
To be washed with water and soap
Air filter
and let dry out every 500 running
(pic. G)
hours or as needed.
Fuel filter
To be cleaned two times during the
(pic. E)
heating season or as needed.
Ignition
To be checked every 500 running
electrodes
hours; distance 4-5 mm.
(pic. C)
To be cleaned every season or as
Fan blades
needed; fan wheel screw to be
tightened with hand.
Maintenance-free, with permanent
Engine
lubrication.
15