en-us
Care and Maintenance

Spray arms

Limescale and contaminants in the rinsing water may
block nozzles and bearings on the spray arms 1:
and 1J.
1.
Check outlet nozzles on the spray arms
for blockages.
Unscrew the upper spray arm 1: (1) and remove
2.
downwards (2).
3.
Remove the lower spray arm 1J upwards.
4.
Clean spray arms under running water.
5.
Re-engage or screw on spray arms.
40

Drain pump

Large food remnants in the rinsing water not retained by
the filters may block the waste water pump. In this case:
9
WARNING
Use caution when removing parts for cleaning as
some debris may be sharp.
1.
Disconnect the appliance from the power supply.
2.
Take out upper rack 12 and lower rack 1j.
3.
Remove the filters 1Z.
4.
Scoop out standing water - use a sponge if
necessary.
5.
Using a spoon, pry off the pump cover (as shown)
until it clicks, then grip the cover and pull upward
until it resists and then pull forward (1). Remove
cover completely.
6.
Check inner compartment and remove any foreign
objects.
9
WARNING
Use caution when removing parts for cleaning as
some debris may be sharp.