Thermador KBULT3655E Guide D'utilisation Et D'entretien page 15

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
≥50%
Chlorine Taste/Odor
≥85%
*
Particulate Class 1
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
Toxaphene
0.003 mg/L
Atrazine
0.003 mg/L
2, 4-D
0.07 mg/L
Asbestos
99%
Cysts‡
99.95%
Turbidity
0.5 NTU
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-LC400V The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter's rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge LC400V, part:
2255709. 2006 suggested retail price of $39.99 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
*
Class I particle size: >0.5 to <1 um
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
††
Fibers greater than 10 um in length
Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Tested and certified by NSF International against ANSI/NSF Standard 42 for the
reduction of Chlorine Taste and Odor, Particulate Class I*; and against
ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,
Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.
Average
Influent Challenge
Influent
Concentration
2.1 mg/L
2.0 mg/L ± 10%
5,366,667/mL
At least 10,000
particles/mL
Average
Influent Challenge
Influent
Concentration
0.152 mg/L†
0.15 mg/L ± 10%
0.143 mg/L†
0.15 mg/L ± 10%
0.0061 mg/L
0.006 mg/L ± 10%
0.0057 mg/L
0.0058 mg/L ± 10%
0.0162 mg/L
0.015 ± 10%
0.220 mg/L
0.225 ± 10%
0.014 mg/L
0.015 ± 10%
0.0086 mg/L
0.009 mg/L ± 10%
0.197 mg/L
0.210 ± 10%
26 x 10
7
10
7
to 10
8
fibers/L††
111,000/mL
50,000/L min.
11.00 NTU
11 ± 1 NTU
Maximum
Average
Effluent
Effluent
0.06 mg/L
0.05 mg/L
4,100/mL**
2,300/mL
Maximum
Average
Effluent
Effluent
0.001 mg/L
0.001 mg/L
0.001 mg/L
0.001 mg/L
0.0004 mg/L
0.0003 mg/L
0.0008 mg/L
0.00051 mg/L
0.0005 mg/L
0.001 mg/L
0.0005 mg/L
0.0005 mg/L
0.0014 mg/L
0.001 mg/L
0.0005 mg/L
0.0005 mg/L
0.058 mg/L
0.0137 mg/L
0.18 x 10
7
mg/L
0.18 x 10
1 mg/L
1 mg/L
0.40 NTU
0.35 NTU
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum%
Average%
Reduction
Reduction
97.1%
97.6%
99.3%
99.9%
Minimum%
Average%
Reduction
Reduction
99.34%
99.34%
99.30%
99.30%
93.5%
96.7%
85.8%
91.2%
96.3%
96.3%
99.7%
99.7%
90%
92.96%
94.25%
94.25%
70.6%
93.06%
7
mg/L
99.93
99.93%
99.99%
99.99%
96.4%
96.8%
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
0.5 GPM (1.89 L/min.) @ 60 psi.
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Kburt3655eKbult3665eKburt3665eKbult3675eKburt3675e

Table des Matières