UP-DOWN (HUM+ HUM-) Set the required humidity among the follows: "CO"
(continuous), "30%", "50%", "35%", "40%", "45%", "50%"...... "85%", "90%",
"AU" (comfort), "CO" (continuous) cycle. The default mode is "CO".
Note: Press UP and DOWN at the same time to convert display of temperature or
humidity, the indicator "Cº" being for temperature and "%" for humidity.
4.
TIMER: Timing setting.
A. In the power-on state, press the TIMER key to set the timer for the scheduled
shutdown. In the off state, press the TIMER key to set the timer and when to start
the dehumidifier.
B. Regular time range: 01~24 hours, timing setting: 000102......232400 cycle.
C. When the timing is set to power on, the timing setting is completed and the timing
is displayed. When the timing is set to off, the timing setting is completed and the
humidity is displayed after 5 seconds.
5.
MODE key: mode conversion: dry clothes, fan, dehumidification.
6.
Child lock: Long key This key is 5 seconds for child lock switch selection.
After child lock is turned on, all button operations except child lock buttons cannot
be operated.
7.
Dual 8-screen display on synchronous main operation display panel.Note: After the
operation is completed 10S, all lights (including double 8) are all dimmed.
OPERATION
1.
Humidity automatic control operation function:
A. When "CO" (continuous) operation is set to dehumidify, the dehumidifier will
continue to operate regardless of the humidity level.
B. If the indoor humidity is higher than or equal to 3% or more of the set humidity,
the compressor and fan will run. The indicator light of the compressor will be on.
C. After the humidity in the room is dehumidified, when the humidity drops below
2% of the set humidity, the compressor is turned off and the dehumidification is
stopped. The indicator lamp (OK lamp) that reaches the humidity is on.
D. If the dehumidifier stops dehumidifying and the humidity in the room rises above
or equal to 3% or more of the set humidity, if the compressor has passed the
three-minute protection status, the compressor will start dehumidifying.
E. According to the above cycle operation, the indoor humidity can be maintained
at the set humidity.
2.
Comfort (shows "AU") function:
A. Below 5°C at room temperature, the dehumidifier stops;
B. 5 °C ≤ room temperature ≤ 20 °C, automatic selection set 60% humidity;
C. 20°C<room temperature ≤27°C, automatically select setting 55% humidity;
D. Room temperature> 27 °C, automatic selection set 50% humidity.
3.
Drying function: (CLOTH light):
A. When this function is enabled, the dehumidifier will continue to operate
(compressor, fan operation) regardless of the humidity level when the "CO"
(continuous) operation dehumidifies.
B. The wind speed is locked at high speed and cannot be adjusted.
4.
Fan:
A. The compressor does not work.
4
66

Publicité

loading