EN
Supply voltage
(see type plate)
Power consumption
Recommended
cable-jacket diameter
Recommended
wire cross-section
Spring-loaded terminal (voltage supply/relay)
Recommended
wire cross-section
Screw terminal (voltage supply)
Recommended
wire cross section
Spring-loaded terminal (external test)
Recommended
wire cross section
Screw terminal (relay/external test)
Recommended
stripping of cable jacket (voltage supply/relay)
Recommended
stripping of cable jacket (external test)
Recommended
length of the wire end tube
Spring-loaded terminal
Recommended
length of the wire end tube
Screw terminal
Connection data of the potential free
contact Switch to load*)
Connection data of the
potential-free contact
Switch to low signal*)
Connection data of the
external test contact
Protection class
Overvoltage category
(IEC 61010-1)
VAC =
V alternating current
VDC = V direct current
*)
The switching of loads means that the properties of the contact are no longer suitable
for the switching of low signals.
6
6. ELECTRICAL DATA
95...240 VAC ±10% (50...60 Hz) /100...125 VDC ±10%
or
24...48 VAC ±10% (50...60 Hz) / 18...72 VDC ±10%
P = 0,6 ... VA (W)
Ø 5,0...10 mm (0,20"...0,9")
0,75...1,5 mm² (AWG 16...20)
0,75...2,5 mm² (AWG 14...20)
0,75...1,0 mm² (AWG 18...20)
0,75...1,5 mm² (AWG 16...20)
~ 0 mm (~ 1.18")
~ 90 mm (~ .54")
8 mm (~ 0.1 inch)
~ 6 mm (~ 0.24 inch)
AC: max. 250V / 1A
DC: max. 0V / 1A
min. 5 VDC / 10 mA
on the unit side 5 VDC; switching current ≥ 0,5 mA
IP 67
II
ingersollrandproducts.com
80442916