Control And Maintenance - Ingersoll Rand ENL 5 Vario Instructions De Montage Et De Service

Masquer les pouces Voir aussi pour ENL 5 Vario:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Compressed air!
Risk of serious injury or death through contact
with quickly or suddenly escaping compressed air
or through bursting plant components or plant
components which are not secured.
measures:
Do not exceed the maximum operating pressure (see
type plate).
Only carry out service measures when the system is
pressure less.
Use pressure-resistant installation material only.
The feed pipe must be tubed firmly. Discharge pipe:
short, fixed pressure hose onto pressure-resistant pipe.
Make sure that persons or objects cannot be hit by
condensate or escaping compressed air.
Supply voltage!
There is the risk of an electric shock involving injury or
death when coming into contact with non-insulated
components carrying supply voltage.
measures:
During electric installations, all regulations in force
need to be adhered to (e.g. VDE 0100 / IEC 6064).
Service measures must only be undertaken when
the system is deactivated.
The removed control unit has no IP degree of
protection.
All types of electrical works must be carried out by
authorized and qualified personnel only.
CAUTION
malfunction during operation!
Through incorrect installation and poor maintenance,
malfunction may occur at the ENL 5 Vario.
Condensate which is not discharged may cause
damage to plants and in production processes.
80442916

11. CONTROL AND mAINTENANCE

DANGER
DANGER
ingersollrandproducts.com
measures:
Condensate drainage which is reliable in performance
directly optimizes the compressed-air quality.
To prevent damage and breakdowns, it is imperative
to observe the following:
Exact compliance with the specifications of use and
with the performance parameters of the ENL 5 Vario,
in connection with the case of application (see "Proper
use" section)
Exact compliance with the installation- and operation
instructions in this manual
Regular maintenance and control of the ENL 5 Vario
in accordance with the instructions in this operating
manual.
It is imperative to observe all hazard statements and
warnings listed here.
Please also observe all regulations and notes regarding
industrial safety and fire prevention at the place of
installation.
As a matter of principle, only use suitable and appropriate
tools and materials in a proper condition.
Do not use aggressive cleaners and improper devices such
as high-pressure cleaners.
Please note that condensates may contain aggressive or
harmful components. Therefore, skin contact should be
avoided.
Condensate is subject to mandatory waste disposal. As
such, it must be collected in suitable containers, and
disposed of or processed properly.
NOTE
EN
15

Publicité

Table des Matières
loading

Table des Matières