Rev.1 17/06/2021
Pag.36
GENERIC ALARM
ANOMALY (general)
Warning Pop-Up
Adjust RDS
RDS SYSTEM ADJUSTMENT
system
(only if the RDS system is provi-
SERVICE REQUEST
AIR FLOW METER FAILU-
(only if the RDS system is provi-
modulate
SIGNALLING
• The door and the ash box are not closed correctly
• Poor combustion in grate.
RUN
BRAZIER CLEANING
(only if the RDS sy-
• Presence of foreign body in air intake tube.
stem is provided)
• The air flow meter may be dirty.
The appearance of the message "ADJUST THE RDS SYSTEM" indicates that the initial parameter testing procedure and
calibration has been unsuccessfully. This indication does not block the stove.
Alarms (table with reference codes)
TITLE
AL
BLACK OUT
01
AL
FUME PROBE
02
AL
FUME OVERTEMP.
03
AL
FUME EXHAUST DAMAGED
04
Use and maintenance manual RBC 8010 - 8012
The stove is in alarm state; refer to the throubleshooting chapter.
The stove has detected an anomaly; refer to the throubleshooting chapter.
FLAME
It shows that the testing procedure and initial parameter calibration have not been completed
REQUEST
or have been performed incorrectly. This indication, however, does not block the stove.
ded)
The threshold value of set work hours has been reached. The symbol displayed remains
active throughout the work phase. Non-routine maintenance is required on the stove.
It shows a failure of the air flow meter and the stove switches to minimum capacity disabling
RE
the RDS system.
ded)
REASON
REASON
- No voltage during work phase
- The fume probe is malfunctioning
- The fume probe is disconnected from the
electronic board
- Combustion in the brazier is not optimal
due to clogging or obstructions of internal
stove ducts
- The tangential fan (if provided) is
malfunctioning or damaged
- Fume exhaust encoder is not working or
is connected incorrectly
- No power to fume exhaust system
- The fume exhaust system is blocked
DESCRIPTION
SOLUTION
• Make sure they are properly closed.
• Switch off the stove, clean the brazier and check the cleanliness of the
support bench, clean the tube bundle by activating the turbolators. and
adjust the combustion through Pellet/Air settings.
• Check for any foreign body and remove it
• Clean the flow meter with the stove in "Switched off" state
• Contact the Support Service
SOLUTION
- Press the switch off key and switch on
boiler switch-on.
- If the problem persists, contact the
Support Service
- Contact the Support Service
- Contact the Support Service
- Switch off the stove, clean the brazier
and the tube bundle and adjust the
combustion setting the Pellet/Air values
- Contact the Support Service
- If the problem persists, contact the
Support
Service
- Contact the Support Service
- Contact the Support Service
- Contact the Support Service