ENGLISH
MAINTENANCE
Warning!
Before carrying out any maintenance operations on the appliance, disconnect the power cable from
the plug.
CLEANING
• Regularly clean the inside and outside of the appliance using only warm water and a neutral detergent.
• Subsequent to washing, rinse with clean water and dry thoroughly using a soft cloth.
• Do not use the following: special glass and mirror cleaning products, liquid, powder, or spray detergents,
alcohol, ammonia or abrasive products.
• If you are not using the refrigerator, we suggest cleaning it well inside and leaving the door ajar to ventilate
the interior.
HELPFUL ADVICE
Where the refrigerator does not function or functions incorrectly, before contacting one of our technical
assistance centres, ensure that:
a) there is a power supply.
b) the voltage complies with that indicated on the plate.
c) the connections and poles are correct.
d) the ventilation grids are not obstructed.
e) the appliance unit is not placed near to a heat source.
f) the power supply fuse is not interrupted.
Warning!
The power cable must only be replaced by qualified technical personnel and by an assistance body
authorised by the Manufacturer.
Indel B will not assume any responsibility in the instance where the instructions in this present
manual are not fully respected.
FAULTS
Number of
flashes
Battery protection cut-out
E1
(The voltage is outside the cut-out setting).
Fan over-current cut-out
E2
(The fan loads the electronic unit with more than 1A
Motor start error
E3
(The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)).
Minimum motor speed error
E4
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed
1,850 rpm).
Thermal cut-out of electronic unit
E5
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is
high, the electronic unit will run too hot).
Faulty temperature sensor
LL
(the temperature sensor is disconnected or defective)
Faulty temperature sensor
HH
(the temperature sensor is defective)
28
TB STEEL DOUBLE DOOR
Error type
).
peak
TB STEEL DOUBLE DOOR_27-04-2018