TB STEEL DOUBLE DOOR
TEMPERATURE CONTROLLER
The electronic Temperature Controller provides the ability to set the desired temperature level and displays
information on the cabinet and set temperature.
The electronic controller has been programmed to maintain an average of the set temperature. The
compressor will start up when the internal cabinet temperature increases 0.5 to 1.5 degrees above that
selected and will run until the temperature is 0.5 to 1.5 degrees below the set temperature.
When your appliance is first connected to AC or DC input the digital read out will show the current cabinet
temperature - the temperature shown on the 'LEFT ZONE TEMP' display corresponds to the larger Left Zone
cabinet; the temperature on the 'RIGHT ZONE TEMP' display corresponds to the stepped Right Zone cabinet.
To adjust the temperature follow these steps:
To increase the cabinet temperature press
Once selected the display will flash a number of times before returning to the current temperature.
When press the above two buttons Set (compressor speed) and
switch the display between °C and °F.
TB STEEL DOUBLE DOOR_27-04-2018
LEFT
ZONE
COOLING
LEFT BIN
HIGH
MID
ON
SET
OFF
LOW
BATTERY PROTECTION
and to decrease press
RIGHT
ZONE
COOLING
RIGHT BIN
MAX
SET
MIN
COMPRESSOR SPEED
until the desired level is reached.
(cooling) at the same time, it would
ENGLISH
23