Electrical Connection - U.s.a. Only - Jenn-Air JDS8850 Instructions Pour L'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Power Supply Cord (optional)
This range is shipped with a specially designed 4-wire power
supply cord. This cord should be used on all new branch circuits,
mobile homes and when local codes prohibit grounding though
the neutral. For a 3-wire power supply cord replacement, service
kit Part Number 74011285 must be used.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Use Phillips screwdriver to remove the terminal block cover
screw located on the back of the range. Pull cover down and
toward you to remove cover.
3. Add strain relief.
Assemble a UL listed strain relief in the opening.
A. UL listed strain relief
Feed the power supply cord through the opening in the
cord/conduit plate on bottom of range. Allow enough
slack to easily attach the wiring to the terminal block.

Electrical Connection - U.S.A. Only

A
Tighten strain relief screw against the power supply cord.
Feed the flexible conduit through the strain relief, allowing
enough slack to easily attach wiring to the terminal block.
Tighten strain relief screw against the flexible conduit.
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire receptacle
A UL listed,
(NEMA type 14-50R)
250-volt
minimum,
40-amp, range
power supply
cord
3-wire receptacle
A UL listed,
(NEMA type 10-50R)
250-volt
minimum,
40-amp, range
power supply
cord
4-wire connection: Power Supply Cord
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
Go to Section:
4-wire connection:
Power supply cord
3-wire connection:
Power supply cord
9