Télécharger Imprimer la page

Master Pumps MPXA81 Traduction Des Instructions D'origine page 14

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Cleaning, maintenance and
ordering of spare parts
The equipment is almost completely maintenance
free. In order to ensure a long service life, however,
we recommend that you regularly check and care
for the product.
The equipment must be
disconnected from the
power supply « OFF » and pull
the power plug prior to
performing any maintenance.
Servicing
_ If the equipment becomes clogged, connect the
discharge line to the water line and disconnect
the suction hose. Open the water line. Switch on
the equipment several times for approx.
two seconds. This should resolve the majority of
clog-related problems.
Replacing the mains cable:
Disconnect the equipment from
the power supply!
A defective mains cable may only
be replaced by a qualified
_ There are no parts inside the equipment which
require additional maintenance.
Storage
_ If the pump is not going to be used for a long
time or has to be removed for the winter months,
rinse it out with water, empty it completely and
allow it to dry.
_ The equipment must be completely drained
before it is subjected to frost.
_ After long stoppages, make sure the rotor turns
correctly by briefly switching the pump on and off.
Technical Data
MPXA81
Mains voltage / frequency
Absorbed power
Type of protection / Insulation class
Suction fitting
Delivery fitting
Maximum flow rate
Maximum head
Maximum suction height including load losses
Power cable
Weight
Maximum dimension of pumped solid particles
Maximum admitted working pressure
Minimum ambient temperature
Maximum ambient temperature
Maximum temperature of the pumped fluid 50° C
Important:
electrician.
230V ~50Hz
800 Watt
IP X4
1"
1"
3.200 l/h
40 m
8 m
1,2 m H07 RNF
10.4 Kg
1 mm
4 bar
5° C
35° C
Maximum number of starts per hour, uniformly
distributed
Noise emission values measured according to
relevant standard.
Acoustic pressure level
Acoustic power level
The sound power pressure may
Weighted root mean square acceleration according
to relevant standard. : < 2.5 m/s²
The declared vibration total value has
been measured in accordance with a standard
test method and may be used for comparing one
tool with another that the declared vibration total
value may also be used in a preliminary
assessment of exposure.
A warning that the vibration emission
during actual use of the power tool can differ
from the declared total value depending on the
ways in which the tool is used and of the need to
identify safety measures to protect the operator
that are based on an estimation of exposure in
the actual conditions of use (taking account of
all parts of the operating cycle such as the times
when the tool is switched off and when it is
running idle in addition to the trigger time).
SERVICE DEPARTMENT
_ Damaged switches must be replaced by our after-
sales service department.
_ If replacing the power cord is necessary, it
should be done by the manufacturer or his agent
to avoid a hazard.
AFTER-SALES SERVICE AND APPLICATION
SERVICE
Our after-sales service responds to your questions
concerning maintenance and repair of your product
as well as spare parts. Exploded views and
information on spare parts can also be found
under:www.eco-repa.com
MASTER PUMPS application service team will
gladly answer questions concerning our products
and their accessories : sav@eco-repa.com
GUARANTEE
Refer to the enclosed guarantee conditions
for the terms and conditions of guarantee.
14
LpA 64 dB(A)
K = 3 dB(A)
LwA 84 dB(A)
K = 3 dB(A)
ATTENTION !
exceed 85 dB(A), in this case
individual hearing protection
must be worn.
40

Publicité

loading