Operating the controller:
Use knobs (1) and (2) to set the temperature and time.
Switch on the on/off switch (3) for operation.
Once switched on, the corresponding display
flashes on the time-scale for approx. 5 seconds.
During this period, the timer can still be changed.
The time period then begins. The display now signals the
remaining time. Once the session has been completed,
the heating switches off and the display flashes '0'.
Switch off the cabin after use (3)!
Information:
To end the session early, set the timer (2) to '0'.
(The heating switches off and the display flashes. Setting a
new time (min. 7.5 minutes) will restart the process again.
Troubleshooting:
Malfunction
No heating or lighting function
No heating function
Heating doesn't switch off
Technical data:
-
Connection: 230 volts ~ 50 Hz , I = 10 A, P = 2.3 kW
-
Ready for operation in 5 minutes
-
Low energy consumption: Approx. 1-2 kW per use
-
Duration of use: Approx. 30 minutes
-
Temperature range: 0 – 80°C
-
Time range: 0 – 60 min
(smallest setting increment 7.5 min.)
Copyright HRB 3662
Measure
Switch device on.
Check mains connection.
Check back-up fuse.
Temperature > Set room temperature.
Timer >7.5 min. (if necessary press on/off switch)
Change temperature sensor to desired value.
Check connector between temperature sensor and controller.
8
Technische Änderungen vorbehalten