Remark:
It is recommended to set up the lowest possible temperature and biggest possible air-
flow. This allows for prolonged use time of the heating element and prevents from da-
maging the IC chips.
If the display is showing the „---„ it means that the output temperature is lower than 100 ⁰C, SMD rework station is
GENERAL REMARKS
1.
in stand by mode, SMD rework gun is placed in the holder.
2.
If the display is showing "S-E" it means that SMD rework gun is having problem with the heat sensor.
3.
When the device is being turned on SMD rework gun should be placed in the holder.
4.
The outlet of the SMD rework gun should be clean and free from any obstacles.
5.
When using small nozzles, it should be remembered that the air flow should be suitable to the diameter of the fixed
nozzle. In order to avoid any SMD rework gun damages, too high air flow along with the high temperature mustn't be
used for a long period of time.
6.
Depending on user's needs, different air flow settings may cause slight variations in temperatures value. The minimum
distance between the outlet of the SMD rework gun and the subject is 2 mm.
7.
Good ventilation of the room in which the appliance is used must be provided. In addition, the device should be placed
in a location with good air circulation to dissipate heat.
SAFETY ISSUES REMARKS
1.
Nozzles should be installed without the use of excessive force, also do not use the pliers or tweezers. Do not over
tighten the mounting screws of the nozzle.
2.
Nozzles can be changed when the SMD rework gun is completely cold.
3.
It is forbidden to use the device near the flammable or combustible elements and objects or at similar places. Tips
and nozzles as well as the air coming out of the SMD rework gun have very high temperature, it is forbidden to touch
these elements as well as it is forbidden to put the hot air directly to face or body. This can cause serious burns.
4.
After long time of use, the outlet of SMD rework gun may be covered with some dust. The outlet should be cleaned
on a regular basis in order to ensure undisturbed air flow.
REPLACEMENT OF SMD REWORK HEATING ELEMENT
10
EN
1. SMD rework gun covers
2. element of the handle
3. heater
4. heater cover
5. outlet pipe
6. nozzle