No.
PROBLEM
Too much vibration
7
The wine cooler seems to make
8
too much noise
9
The door will not close properly.
10 The door is not at level with the cabinet
11 The door is opening by itself
12 A shelf is not at level
13 After inserting the key the cellar still lock
14 There is water on the cellar floor
15 Accumulation of water inside the cellar?
16 Frost on the evaporator?
Steaming/humidity between the thermal
17
windows
The display window is shown with "HH"
or "LL" instead of a digital figure,
18
and/or with continuous buzz sound.
PROBLEM POSSIBLE CAUSE / MEASURE
Check to assure that the appliance is level.
Check to assure no parts inside the cabinet or in the
compressor chamber are loose.
The rattling noise may come from the flow of the refrigerant,
which is normal.
As each cycle ends, you may hear gurgling sounds caused by
the flow of refrigerant.
Contraction and expansion of the inside walls may cause
popping and crackling noises.
The appliance is not level.
The wine cooler is not level.
The door was reversed and not properly installed.
The gasket is dirty.
The shelves are out of position.
Adjust the legs at the front of the cellar until the door is at
level with the cabinet.
It is probably because the guide is not equal to the « L »
piece.
Make sure the cellar is at level.
Make sure the guide are well engage
The handle(lock) is not notch or the nut is not equal to the « L
» piece.
Make sure the door is at level with the cabinet
Make sure the drain is in the evaporation tray in the back of
the cellar. If so, during humid temperature, you might have to
wipe off the excess in the tray with a sponge
This phenomena might occurs in summer, reason of humidity.
Verify if the door seal is hermetic.
It is recommended during humid temperature to wipe off the
excess of water inside the cellar.
It is normal when the water vapor freeze. However when the
cooling cycle is finish, the ice will become water.
During summer with humid temperature, this situation might
occurs.
The temperature probe is out of order.