TECHNICAL DATA
Definition in accordance with EN
Constructive system
Nominal power in kW
Efficiency in %
smoke outlet diameter in mm
Chimney height ≥ (m) - dimension (mm)
Chimney draught in Pa (mm H
Hourly consumption in kg/h
CO measured at 13% oxygen in %
Exhaust gas emission in g/s – wood
Exhaust gas temperature in °C - wood
Hearth opening size in mm (W x H)
Hearth size in mm (W x H x D)
Oven size in mm (W x H x D)
Type of grill
Height in mm
Width in mm
Depth in mm
Weight in kg
Fire prevention safety distances
heatable m
3
(30 kcal/h x m
For those buildings in which the thermal insulation does not correspond to the instructions on heat protection, the heating volume of the
(*)
product is: favourable type of building (30 kcal/h x m
kcal/h x m
).
3
**) The proposed value are indicative. The installation must, in any case, be sized and verified according to the general calculation method in UNI
EN13384-1 or by another method of proven efficiency.
With thermal insulation in accordance with the regulations regarding energy saving, the heated volume is greater. With temporary heating, in
the event of interruptions which last more than 8 hours, the heating capacity is reduced by about 25%.
ThE DECLARED TEChNICAL DATA hAVE bEEN AChIEVED by bURNING bEECh WOOD CLASS "A1" ACCORDING TO ThE REqUIREMENT UNI EN ISO
17225-5 AND WOOD MOISTURE CONTENT LESS ThAN 20%. by bURNING A DIffERENT kIND Of WOOD ThE EffICIENCy Of ThE PRODUCT ITSELf
COULD ChANGE AND SOME SPECIfIC ADjUSTMENTS ON ThE APPLIANCE COULD bE NEEDED.
TECHNICAL DEsCRIPTION
The fire cookers of La NORDICA are suitable to cook on the grill and on the oven and to heat living spaces for some periods or to support an
insufficient centralized heating system. They are ideal for holiday apartments and weekend houses or as an auxiliary heating system during
the whole year. As fuel, wood logs are used. The appliance works as an intermittent operating appliance.
The fire cooker is made of galvanized and enamelled steel sheets and enamelled cast iron (doors, front side, plate ).
The hearth is totally sheathed with single cast iron sheets. Inside there is a flat grate. The hearth is equipped with a panoramic door with
ceramic glass (resistant up to 700 °C). This allows a wonderful view on the burning flames. Furthermore, it is thus avoided the output of sparks
and smoke. Heat resistant glove or fire hook already INCLUDED.
As an OPTIONAL it is available also a chromium plated grate for the oven.
Under the oven door there is an food warmer holder, with the related closing door: NEVER introduce flammable objects or materials
(Picture 6
C). Below the food warmer holder there is an extractable wood drawer, with the related closing door (D).
ACCEssORIEs
The heating of the environment is made by irradiation: through the panoramic glass and the external hot surfaces of the cookers, the heat
is radiated into the environment.
The cooker is equipped with controls of primary and secondary air by which it is adjusted the combustion air.
1A - PRIMARY Air Register
(Picture 6
With the lower register, the passage of primary air in the lower part of the cooker is regulated through the ash drawer and the grill in the
direction of the fuel. The primary air is necessary for the combustion process. The ash drawer must be emptied regularly, so that the ash
cannot block the primary air intake for combustion. The primary air also keeps the flame alive.
The primary air register must be almost completely closed during wood combustion, as otherwise the wood burns too quickly and the
cooker may overheat.
24
O)
2
(wood with 20% humidity)
)
3
); less favourable type of building (40 kcal/h x m
3
CHROME PLATED OVEN GRILLE
OPTIONAL
).
ROsA Reverse
EN 12815
2
8,1
81,1
150
(**) 4 - 200x200 Ø200
12 (1,2 mm H
2,3
0,07 - (910 mg/Nm
7,8
237
349 x 235
374 x 290 x 320
245 x 300 x 384
855
1030
650
183
232 (*)
POKER
INCLUDED
ENgLIsH
ROsA sinistra Reverse
EN 12815
8,2
86,5
150
(**) 4 - 200x200 Ø200
O)
12 (1,2 mm H
2
2,3
)
0,05 - (609 mg/Nm
3
6,9
189
349 x 235
374 x 290 x 320
245 x 300 x 384
Movable - flat
855
1030
650
183
Chapter FIRE SAFETY
235 (*)
); unfavourable type of building (50
3
GLOVE
INCLUDED
1
O)
2
)
3